FlareHawk FHPACS0025TTSRecalls & reported problems
Integrity Implants Inc. · Shell, Short 25 mm, TiH9 Sterile · Class 2 · Implant
All models of FlareHawk (29)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810045530895), received between Aug 22, 2024 and Aug 22, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device-Device Incompatibility1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 22, 2024Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT THERE WAS A CASE WHERE A SHIM AND SHELL MISMATCH OCCURRED. A FH9 SHORT SHELL WITH AN FH11 10/12MM SHIM WAS USED AND THIS WAS NOTED WHEN THE SALES ORDER FORM WAS SUBMITTED. A REVISION SURGERY WAS CONDUCTED TO CORRECT THE ERROR. A FOLLOW UP WITH DR. (B)(6) WAS CONDUCTED BY (B)(4) TO OBTAIN ADDITIONAL INFORMATION ABOUT THE EVENT. DR. (B)(6) SAID THEY USED THE LOCK CHECK GAUGE AND THE GUIDE PIN WAS FLUSH WITH THE TOP OF THE INSTRUMENT AND READ AS 'LOCKED'. HE ALSO SAID THAT DR. (B)(6) RARELY USES FH9 AND THE SOFT IMPLANT CASE WASN'T EVEN IN THE OPERATING ROOM. THE FH11 IMPLANTS WERE THE ONLY IMPLANTS IN THE ROOM, WHICH MAKES IT MORE LIKELY THAT THE RESTOCK WAS IN THE WRONG CASE. BOTH NATE BATES AND I WERE ON THE CALL WITH DR. (B)(6) AND WE DISCUSSED THE PROBABILITY THAT THE IMPLANT WAS NOT LOCKED AND ASKED THAT HE SEND IMAGES TO VERIFY. DR. (B)(6) WAS ABLE TO GET THE A/P AND LATERAL IMAGES AND NATE ASSESSED THAT THE WINGS OF THE CORE ARE BROKEN IN THE A/P, WHICH COULD EXPLAIN WHY THE LOCK GAUGE SHOWED THAT THE IMPLANT WAS LOCKED. I ASKED (B)(6) TO SEND BACK THE IMPLANT FOR ASSESSMENT. AFTER HAVING A DISCUSSION WITH DR. (B)(6), DR. (B)(6) DECIDED TO SCHEDULE THE PAT
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20033683 ↗
Other Intervertebral Fusion Device With Bone Graft, Lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page