aprevo H.L23.02Recalls & reported problems
Carlsmed, Inc. · aprevo TLIF-O L2/L3, plan · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810056990763), received between Jul 10, 2023 and Jul 10, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Unintended Movement” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Unintended Movement1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 10, 2023Unintended Movement; Unintended Movement
ON (B)(6) 2023 AN EVENT WAS REPORTED BY CARLSMED'S DIRECTOR OF SALES, (B)(4), REGARDING DR. (B)(6) CASE WITH LOT CODE, 230504.BK.01 PERFORMED ON (B)(6) 2023. THE CASE WAS PLANNED WITH A SINGLE LEVEL L23 APREVO TLIF-OBLIQUE (LEFT SIDED APPROACH). THE DATE OF THE EVENT WAS (B)(6) 2023. DURING THE PLACEMENT OF THE L23 TLIF-O INTERVERTEBRAL BODY FUSION DEVICE (REFERRED TO AS THE 'DEVICE' IN THIS SECTION), THE DEVICE ROTATED MEDIALLY TOWARDS THE SPINAL CORD. THE CORNER EDGE OF THE DEVICE CAME INTO CONTACT WITH THE ANATOMY OF THE SPINAL CORD, RESULTING IN A DURAL TEAR. THE TEAR REQUIRED INTERVENTION, AND THE SURGEON SPENT AN ADDITIONAL 10-15 MINUTES TO REPAIR THE DURAL TEAR. IT WAS REPORTED THAT THE DEVICE WAS FULLY SEATED AND THREADED ONTO THE INSTRUMENT. ACCORDING TO THE SURGEON, THE PATIENT IS IN GOOD CONDITION WITH NO REPORTS OF ANY LONG TERM SYMPTOMS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17286756 ↗
Other Intervertebral Fusion Device With Bone Graft, Lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page