Carrier™ Delivery Catheter CR7074Recalls & reported problems
Balt USA LLC · The Carrier™ Delivery Catheter is a single lumen, variable stiffness, composite catheter. The design facilitates the advancement of the catheter and is intended to assist the delivery of interventional devices in the peripheral and neurovasculature. The outer surface of the Carrier™ Delivery Catheter is coated with a hydrophilic coating to increase lubricity. The proximal end of the Carrier™ Delivery Catheter incorporates a luer fitting for the attachment of accessories. Two radiopaque markers at the distal end help to facilitate fluoroscopic visualization. A Steam Shaping Mandrel and Peel-away Introducer Tube are included within the tray. The Carrier™ Delivery Catheter is provided sterile, non-pyrogenic, and is intended for single use only. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 1
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00810068561982), received between Aug 21, 2024 and Feb 27, 2026 — classified as 1 death, 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Perforation of Vessels1
- Vascular Dissection1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
DeathFeb 27, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT: "TEXT RECEIVED FROM THE PHYSICIAN "HAD VESSEL RUPTURE WITH RAPTOR/CARRIER LAST NIGHT. I DON'T THINK IT WAS DEVICE RELATED. PULLED OUT A LONG FIRM CLOT ON 6TH PASS AND HAD EXTRAV FROM M1 PROBABLY AVULSED M2 PT DIED"" UPDATE 28JAN2026 - ADDITIONAL INFORMATION RECEIVED FROM THE ISSUER: "PASSING ALONG THIS COMPLAINT. I DO NOT YET HAVE SPECIFIC REFERENCE NUMBERS OR LOTS; WILL FORWARD WHEN THEY BECOME AVAILABLE. WANTED TO DOCUMENT BECAUSE PATIENT DEATH WAS REPORTED. PHYSICIAN DOES NOT BELIEVE THIS WAS A DEVICE RELATED INJURY."
Patient problems: Perforation of Vessels
MAUDE report 24475681 ↗InjuryAug 21, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT: "PHYSICIAN DISSECTED M1. M1 TAKEOFF WAS TORTUOUS AND THE CASE WAS CHALLENGING. ORIGINALLY REPORTED (B)(6) 2024 IN LMR FORM AND MANAGEMENT REPORT IN IPHONE NOTES. THE PHYSICIAN DID NOT USE A GUIDEWIRE WITH CARRIER. HE CONFIRMED THAT HE IS NOT SURE IT WAS THE CARRIER THAT DISSECTED THE M1, AS MANY OTHER SYSTEMS WERE USED IN THE CASE INCLUDING A SEPARATE GUIDEWIRE & MICROCATHETER SYSTEM AND A STENT RETRIEVER. PHYSICIAN MENTIONED HE WOULD CONSIDER USING A WIRE NEXT TIME WITH DIFFICULT ANATOMY." INCIDENT REPORT FORM SUBMITTED FOR THIS COMPLAINT INDICATES THAT NO PATIENT INJURY WAS SUSTAINED.
Patient problems: Vascular Dissection
MAUDE report 20009473 ↗
Other Catheter, Percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page