Skip to content

HTR-PEKK PK625635Recalls & reported problems

Oxford Performance Materials, Inc. · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810077248515), received between Mar 7, 2023 and Mar 7, 2023 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Unspecified Infection1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 7, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE CASE SALES REP INFORMED OPM THAT THE IMPLANT HAD TO BE EXPLANTED DUE TO AN INFECTION IN THE PATIENT. THE REP CONFIRMED THAT THE INFECTION WAS DUE TO PATIENT NON-COMPLIANCE. THE SURGEON REQUESTED AN EXACT REPLICA OF THE INITIAL IMPLANT AS A REPLACEMENT. IMPLANTATION AND EXPLANTATION DATES ARE NOT KNOWN.

    Patient problems: Unspecified Infection

    MAUDE report 16499649 ↗

FDA clearance and classification

Cleared through 510(k) K180064 on Jul 27, 2018 (decision: Substantially Equivalent). Submitted by Oxford Performance Materials, Inc. as “OsteoFab Patient Specific Cranial Device”. The FDA review took 199 days. FDA record ↗

The FDA regulates product code GXN (plate, cranioplasty, preformed, non-alterable) under 21 CFR 882.5330 as a Class II device. 21 CFR 882.5330 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the HTR-PEKK PK625635

Has the HTR-PEKK PK625635 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00810077248515), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the HTR-PEKK PK625635?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 7, 2023. That report lists patient problem “Unspecified Infection” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the HTR-PEKK PK625635?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the HTR-PEKK PK625635 FDA approved?

It was cleared through 510(k) K180064 on Jul 27, 2018. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the HTR-PEKK PK625635 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.

Who makes the HTR-PEKK PK625635, and is it still sold?

The FDA's device database lists Oxford Performance Materials, Inc. as the company responsible for it (brand HTR-PEKK, model PK625635). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Plate, Cranioplasty, Preformed, Non-Alterable devices

All Plate, Cranioplasty, Preformed, Non-Alterable devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page