272 SmartScope Laser Fiber FT-0272S-RT-00C-FOR-1Recalls & reported problems
Optical Integrity Inc · 272 SmartScope Laser Fiber · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00810077630648), received between May 20, 2024 and Jun 12, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 12, 2024Break; Break
DURING A UROLOGY PROCEDURE THE FIBER BROKE THAT RESULTED IN A BURN TO THE PHYSICIAN'S GLOVE. THE FIBER "SNAPPED IN HALF" AND "BURNED THE PHYSICIAN'S GLOVE." IT COULD NOT BE VERIFIED HOW THE FIBER BROKE OR IF THE BURN WAS THROUGH THE GLOVE AND CAUSED INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19519081 ↗MalfunctionMay 20, 2024
DURING LEFT URETEROSCOPY PROCEDURE , LASER WAS BEING USED, SURGEON NOTIFIED STAFF THAT A SMALL PLASTIC PIECE HAD COME OFF DURING PROCEDURE. PIECE WAS RETRIEVED C-ARM WAS BEING USED FOR PROCEDURE - NO EVIDENCE OF ANY RETAINED PIECES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19351238 ↗
Other Powered Laser Surgical Instrument devices
- Moxy 0010-2400Boston Scientific Corporation · Powered Laser Surgical Instrument4,572 reports
- SOLTIVE TFL-PLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls450 reports
- Flexiva TracTip M0068403960Boston Scientific Corporation · Powered laser surgical instrument562 reports
- Moses™ AC-10030100Lumenis Ltd. · Powered Laser Surgical Instrument532 reports
- Flexiva M0068403910Boston Scientific Corporation · Powered laser surgical instrument376 reports
- Visualase 9735542Medtronic Navigation, Inc. · Powered laser surgical instrument1 recall2 deaths311 reports
- SOLTIVE TFL-SLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls33 reports
- NeuroBlate® System 20980Monteris Medical Inc · Powered laser surgical instrument7 deaths296 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page