Penumbra, Inc. · Indigo System Lightning Flash Aspiration Tubing, Aspiration Catheter 16 100cm XTORQ Tip, Select+ 120cm H1 Tip · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810169722541), received between Mar 13, 2026 and Mar 13, 2026 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Perforation of Vessels1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 13, 2026Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE LEFT AND RIGHT LUNGS USING AN INDIGO SYSTEM FLASH ASPIRATION CATHETER (FLASH CATHETER), AN ELEMENT VASCULAR ACCESS SHEATH (ELEMENT), A NON-PENUMBRA CATHETER, A NON-PENUMBRA SHEATH, GUIDEWIRE, AND A MICRO ACCESS KIT. AFTER SUCCESSFULLY TREATING THE RIGHT LOBE USING THE FLASH CATHETER, THE GUIDEWIRE AND THE FLASH CATHETER WERE ADVANCED INTO THE LEFT PULMONARY ARTERY. TWO SUCCESSFUL PASSES WERE COMPLETED USING THE FLASH CATHETER IN THE LEFT LOWER LOBE. THE GUIDEWIRE WAS FIRST ADVANCED INTO THE SUB-SEGMENTAL BRANCH OF THE LOWER LEFT LOBE AND THE FLASH CATHETER WAS THEN ADVANCED OVER THE GUIDEWIRE TOWARD THE BRANCH. THE GUIDEWIRE WAS RETRACTED INTO THE FLASH CATHETER TO PERFORM A CONTRAST INJECTION. IT WAS REPORTED THAT THE PATIENT STARTED TO COUGH UP BLOOD. THE CONTRAST INJECTION REVEALED CONTRAST STAINING ON THE SUB-SEGMENTAL BRANCH OF THE LOWER LEFT LOBE. THE FLASH CATHETER WAS REMOVED. A NON-PENUMBRA BALLOON DEVICE (6MM) WAS USED TO STOP THE BLEED UNDER FLUOROSCOPY. THE PHYSICIAN REPORTED IT IS UNCLEAR IF THE GUIDEWIRE OR THE FLASH CATHETER ATTRIBUTED TO THE VESSEL PERFORATION. THE PATIENT WAS REPORTED TO BE STABLE AND DOING

    Patient problems: Perforation of Vessels

    MAUDE report 24596291 ↗

Other Peripheral Mechanical Thrombectomy With Aspiration devices