ENROUTE Transcarotid Stent SR-0730-CSRecalls & reported problems
Silk Road Medical, Inc. · 7 mm X 30 mm · Class 3 · Implant
All models of ENROUTE Transcarotid Stent (14)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 7
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00811311020430), received between Aug 7, 2023 and Dec 2, 2025 — classified as 7 injuries.
The most frequently reported specific device problem is “Defective Device” (2 reports).
1 other recall cover devices cleared under the same FDA submission (P140026); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem4
- Defective Device2
- Positioning Problem1
Patient problems
- Ischemia Stroke2
- Stroke/CVA2
- Thrombosis/Thrombus2
- Low Blood Pressure/ Hypotension1
- No Clinical Signs, Symptoms or Conditions1
- Obstruction/Occlusion1
- Vascular Dissection1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
InjuryDec 2, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A DISSECTION WAS IDENTIFIED RESULTING IN AN ADDITIONAL STENT PLACEMENT. AN ENROUTE TRANSCAROTID STENT WAS SELECTED FOR USE IN A LEFT SIDED TRANSCAROTID ARTERY REVASCULARIZATION (TCAR) PROCEDURE. DURING THE TCAR PROCEDURE, THE PHYSICIAN ADVANCED THE 0.014" GUIDEWIRE INTO THE INTERNAL CAROTID ARTERY (ICA), PRE-DILATED, PLACED AN ENROUTE STENT, AND POST-DILATED SUCCESSFULLY. IMAGING WAS THEN PERFORMED, AND IT REVEALED A DISSECTION JUST BEYOND THE DISTAL PORTION OF THE STENT IN THE ICA. THE PHYSICIAN ATTRIBUTED THE DISSECTION EVENT TO EITHER THE ENROUTE 0.014" GUIDEWIRE OR THE ENROUTE STENT AND ELECTED TO PLACE AN ADDITIONAL STENT TO COVER THE DISSECTION.
Patient problems: Vascular Dissection
MAUDE report 23695022 ↗InjuryJul 2, 2025Positioning Problem; Positioning Problem
IT WAS REPORTED THAT THE STENT WAS INADVERTENTLY DEPLOYED A COLLATERAL VESSEL THAT CAME OFF THE ICA, REQUIRING ADDITIONAL SURGICAL INTERVENTION. AN ENROUTE TRANSCAROTID STENT WAS SELECTED FOR USE IN A RIGHT SIDED TRANSCAROTID ARTERY REVASCULARIZATION (TCAR) PROCEDURE. THE DISTAL PORTION OF THE STENT WAS INADVERTENTLY DEPLOYED IN A COLLATERAL VESSEL THAT CAME OFF THE INTERNAL CAROTID ARTERY (ICA) AND THE PROXIMAL PORTION OF THE STENT WAS DEPLOYED IN THE ICA. THE PHYSICIAN ELECTED TO CONVERT THE PROCEDURE TO A CAROTID ENDARTERECTOMY (CEA), EXPLANT THE STENT, AND USE A POLYTETRAFLUOROETHYLENE (PTFE) GRAFT INSTEAD OF A CAROTID PATCH.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22385659 ↗InjuryJun 6, 2025Defective Device; Defective Device
IT WAS REPORTED THAT THE PATIENT EXPERIENCED STROKE-LIKE SYMPTOMS 1 WEEK POST T-CAR, AND THE STENT APPEARED NARROWED. TWO ENROUTE TRANSCAROTID STENTS WAS SELECTED FOR USE IN A RIGHT SIDED TRANSCAROTID ARTERY REVASCULARIZATION (TCAR) PROCEDURE. THERE WERE NO ISSUES WITH THE STENTS EXPANDING NOTED DURING THE PROCEDURE OR IN POST PROCEDURE IMAGING. ONE WEEK FOLLOWING THE TCAR PROCEDURE, THE PATIENT PRESENTED TO THE ER WITH STROKE-LIKE SYMPTOMS. THE PATIENT WAS TRANSFERRED TO A DIFFERENT FACILITY, AND THE PHYSICIAN HAD LIMITED ACCESS TO ADDITIONAL INFORMATION. THE PHYSICIAN WAS ABLE TO REPORT THAT ONE OF THE STENTS APPEARED NARROWED. NO FURTHER INFORMATION WAS AVAILABLE, DESPITE REQUEST BY BOSTON SCIENTIFIC.
Patient problems: Stroke/CVA
MAUDE report 22159367 ↗InjuryMay 30, 2025Defective Device; Defective Device
IT WAS REPORTED THAT THE PATIENT EXPERIENCED STROKE-LIKE SYMPTOMS 1 WEEK POST TCAR, AND THE STENT APPEARED NARROWED. TWO ENROUTE TRANSCAROTID STENTS WERE SELECTED FOR USE IN A RIGHT SIDED TRANSCAROTID ARTERY REVASCULARIZATION (TCAR) PROCEDURE. THERE WERE NO ISSUES WITH THE STENTS EXPANDING NOTED DURING THE PROCEDURE OR IN POST PROCEDURE IMAGING. ONE WEEK FOLLOWING THE TCAR PROCEDURE, THE PATIENT PRESENTED TO THE ER WITH STROKE-LIKE SYMPTOMS. THE PATIENT WAS TRANSFERRED TO A DIFFERENT FACILITY, AND THE PHYSICIAN HAD LIMITED ACCESS TO ADDITIONAL INFORMATION. THE PHYSICIAN WAS ABLE TO REPORT THAT ONE OF THE STENTS APPEARED NARROWED. NO FURTHER INFORMATION WAS AVAILABLE, DESPITE REQUEST BY BOSTON SCIENTIFIC.
Patient problems: Stroke/CVA
MAUDE report 22114138 ↗InjuryApr 9, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT AFTER A LEFT TRANSCAPHOID ARTERY REVASCULARIZATION (TCAR) PROCEDURE, THE PATIENT EXPERIENCED BARORECEPTOR DYSFUNCTION. THE PATIENT REMAINED AN INPATIENT FOR THREE DAYS POST PROCEDURE AND WAS GIVEN NOREPINEPHRINE UNTIL THE BARORECEPTORS NORMALIZED. IT IS UNKNOWN IF THE ENROUTE TRANSCAPHOID STENT SYSTEM (TSS) CONTRIBUTED TO BARORECEPTOR DYSFUNCTION AND THEREFORE, THIS REPORT WILL BE REPORTED OUT OF AN ABUNDANCE OF CAUTION.
Patient problems: Low Blood Pressure/ Hypotension
MAUDE report 19076246 ↗InjuryOct 4, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT 9 DAYS AFTER A TRANSCAROTID ARTERY REVASCULARIZATION (TCAR) PROCEDURE, THE PATIENT EXPERIENCED ACUTE STROKE WITH AN OCCLUDED STENT. THROMBECTOMY WAS PERFORMED TO ADDRESS THE ISSUE. ADDITIONAL INFORMATION INDICATED THAT THE PATIENT'S CONDITION HAD NOT YET RESOLVED. AT THIS TIME, IT IS UNKNOWN IF THE REPORTED EVENT IS RELATED TO PROCEDURAL ISSUES, NON-COMPLIANCE OR RESISTANCE TO MEDICATION, OR A SILK ROAD MEDICAL DEVICE FAILURE, HENCE, THE EVENT WILL BE REPORTED OUT OF ABUNDANCE OF CAUTION.
Patient problems: Ischemia Stroke; Obstruction/Occlusion; Thrombosis/Thrombus
MAUDE report 17873337 ↗InjuryAug 7, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT AFTER THE COMPLETION OF A LEFT TRANSCAROTID ARTERY REVASCULARIZATION (TCAR) PROCEDURE, THE PATIENT HAD A STROKE WITH A LEFT-SIDED INFARCT. THE PHYSICIAN PERFORMED A THROMBECTOMY TO ADDRESS THE ISSUE. AT THIS TIME, IT IS UNKNOWN IF THE REPORTED EVENT IS RELATED TO PROCEDURAL ISSUES, PATIENT RESISTANCE OR NON-COMPLIANCE TO MEDICATION, OR A SILK ROAD MEDICAL DEVICE FAILURE, HENCE, THE EVENT WILL BE REPORTED OUT OF ABUNDANCE OF CAUTION.
Patient problems: Ischemia Stroke; Thrombosis/Thrombus
MAUDE report 17476382 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P140026. One submission often covers many models, so check the product and lot details in each record.
- Z-1146-2021 · Jan 13, 2021 · TerminatedENROUTE Transcarotid Stent System REF SR-XXYY-CS
Other Stent, Carotid devices
- Neuroguard IEP® System NG-0740-140-2Contego Medical, Inc. · Stent, Carotid2 recalls32 reports
- Neuroguard IEP® System NG-NV-6-40Contego Medical, Inc. · Stent, Carotid2 recalls9 reports
- Neuroguard IEP® System NG-NV-7-40Contego Medical, Inc. · Stent, Carotid2 recalls8 reports
- ENROUTE Transcarotid Stent SR-0940-CSSilk Road Medical, Inc. · Stent, Carotid1 recall5 deaths58 reports
- Neuroguard IEP® System NG-0640-140-2Contego Medical, Inc. · Stent, Carotid2 recalls7 reports
- ENROUTE Transcarotid Stent SR-1040-CSSilk Road Medical, Inc. · Stent, Carotid1 recall3 deaths56 reports
- CGuard Prime Carotid Stent System CND0840Inspire M.D Ltd · Stent, Carotid1 recall1 death41 reports
- CGuard Prime Carotid Stent System CND0940Inspire M.D Ltd · Stent, Carotid1 recall31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page