TracStar™ Large Distal Platform ICAC088105Recalls & reported problems
Imperative Care, Inc. · TracStar™ 6F 088 LDP, 105 cm · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00812212030139), received between Nov 19, 2019 and May 13, 2020 — classified as 2 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Insufficient Device Problem Information1
Patient problems
- Fistula1
- Rupture1
- Thrombus1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMay 13, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A THROMBECTOMY WAS PERFORMED TO TREAT OCCLUSIONS IN THE LEFT SEGMENT OF THE MIDDLE CEREBRAL ARTERY (MCA). ONE OCCLUSION WAS OBSERVED IN THE M1 MCA, ALONG WITH MULTIPLE OCCLUSIONS WITHIN THE M3 MCA. THE TRACSTAR 088 LDP 105CM CATHETER WAS DELIVERED OVER A GUIDEWIRE AND 027 MICROCATHETER TO THE DISTAL INTERNAL CAROTID ARTERY (ICA). THE PHYSICIAN THEN ADVANCED A REPERFUSION CATHETER AND 3X20MM STENT RETRIEVER THROUGH TRACSTAR AND USED THESE DEVICES TO REMOVE THE CLOTS FROM THE M1 MCA AND M3 MCA. MULTIPLE ATTEMPTS WERE REQUIRED TO REMOVE ALL OF THE CLOTS AND THE TRACSTAR CATHETER WAS REPOSITIONED DURING THESE ATTEMPTS. REPERFUSION WAS ACHIEVED AFTER OVER AN HOUR OF TREATMENT WITH A FINAL TICI 2B SCORE. FOLLOW UP MRI PERFORMED THE NEXT DAY FOUND A COMPLETE OCCLUSION OF THE LEFT CAROTID ARTERY AND A FULL HEMISPHERIC STROKE THAT REQUIRED TREATMENT VIA A HEMICRANIECTOMY. THE PHYSICIAN REVIEWED THE FINAL ANGIOGRAPHIC RUNS OF THE THROMBECTOMY FOR POTENTIAL CAUSES OF THE OCCLUSION AND NOTED SMALL MICROLESIONS IN THE ICA, BUT SAW NO CLEAR VESSEL DISSECTION OR INJURY THAT WOULD HAVE CONTRIBUTED TO THE EVENT. AT THIS TIME, THE CAUSE OF THE ICA OCCLUSION IS UNKNOWN.
Patient problems: Thrombus
MAUDE report 10054294 ↗InjuryNov 19, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE TO TREAT AN OCCLUSION IN THE M2/M3 SEGMENT OF THE MIDDLE CEREBRAL ARTERY (MCA). THE IMPERATIVE CARE TRACSTAR 088 LDP WAS USED AS THE ACCESS CATHETER TO SUPPORT DELIVERY OF A PENUMBRA 3MAX REPERFUSION CATHETER AND A GUIDEWIRE. ALL THREE DEVICES WERE ADVANCED TO THE CAVERNOUS SEGMENT OF THE INTERNAL CAROTID ARTERY (ICA), THEN THE PHYSICIAN CONTINUED TO ADVANCE THE 3MAX AND GUIDEWIRE TO THE SITE OF THE OCCLUSION. ASPIRATION WAS SUCCESSFULLY PERFORMED USING THE 3MAX AND IT WAS REMOVED FROM THE PATIENT. SUBSEQUENTLY, THE PHYSICIAN DECIDED TO TREAT CAROTID ATHEROSCLEROSIS NOTED EARLIER IN THE PROCEDURE AND PULLED THE TRACSTAR BACK TO PERFORM A CONTRAST IMAGING RUN. ON THE IMAGING RUN, THE PHYSICIAN NOTED A CAROTID CAVERNOUS FISTULA (CCF) THAT WASN'T PRESENT AT THE START OF THE PROCEDURE. AS THE TRACSTAR, 3MAX, AND GUIDEWIRE WERE ALL ADVANCED THROUGH THE CAVERNOUS ICA IT IS POSSIBLE THAT ONE OF THESE DEVICES CAUSED THE CCF. THE PHYSICIAN CONTINUED THE PROCEDURE TO TREAT THE CAROTID ATHEROSCLEROSIS AND DECIDED THAT THE CCF DID NOT REQUIRE IMMEDIATE TREATMENT AS IT WAS SLOW FILLING AND ASYMPTOMATIC. WHILE THE PATIENT WAS ASYMPTOMATIC FOLLO
Patient problems: Fistula; Rupture
MAUDE report 9345017 ↗
Other Catheter, Percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page