Zoom 88 Large Distal Platform Support ICTC088100SRecalls & reported problems
Imperative Care, Inc. · Zoom 88 088 LDP Support, 100 cm · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00812212030573), received between Jul 29, 2026 and Jul 29, 2026 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Material Separation1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 29, 2026Break; Material Separation
It was reported that during a carotid stent procedure, a Zoom 88 Support catheter became kinked approximately 14 cm from the distal tip while positioned in the iliac artery. During the first pass, resistance was encountered during advancement at which time the kink at 14cm was observed. Resistance was also encountered during retraction while attempting to exchange the catheter for a new Zoom 88 Support. As the physician attempted to withdraw the catheter, it fractured approximately 14 cm from the distal tip. A goose neck snare was used in an attempt to retrieve the detached catheter segment; however, retrieval was unsuccessful, and the fragment remained in the common iliac artery without limiting blood flow. Open surgical intervention was subsequently performed to access the iliac artery and retrieve the distal catheter fragment. The catheter segment was successfully retrieved, and the patient was reported to be alive following the procedure.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50064306 ↗
Other Catheter, Percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page