Skip to content

Pounce ™ XL Thrombectomy PTS-1011-7F135Recalls & reported problems

Surmodics, Inc. · Pounce XL Arterial Thrombectomy Sytem · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00812339030807), received between Jul 10, 2025 and Jul 10, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Difficult to Remove” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Remove1
  • Fracture1

Patient problems

  • Foreign Body In Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 10, 2025Fracture; Difficult to Remove; Fracture; Difficult to Remove

    A PATIENT PRESENTED WITH NO FLOW THROUGH A 6MM GRAFT FROM THE RIGHT COMMON FEMORAL ARTERY (RCFA) TO THE POSTERIOR TIBIAL ARTERY (PT). LEFT COMMON FEMORAL ACCESS WAS OBTAINED USING A 7F SHEATH, LATER EXCHANGED FOR AN 8F SHEATH TO ACCOMMODATE MULTIPLE THROMBECTOMY PASSES. TWO SUCCESSFUL PASSES WERE COMPLETED USING THE POUNCE XL IN CHRONIC RIGHT-SIDED VESSELS AND THE OCCLUDED BYPASS SEGMENT. DURING A THIRD PASS THROUGH THE NATIVE RCFA, A SUBSTANTIAL QUANTITY OF ORGANIZED THROMBUS WAS CAPTURED IN THE DEVICE FUNNEL AND BASKETS. UPON ATTEMPTING TO REMOVE THE LOADED SYSTEM THROUGH THE 8F SHEATH, RESISTANCE WAS ENCOUNTERED. THIS WAS PRESUMED TO BE DUE TO THE THROMBUS VOLUME BURDENING THE LUMEN CLEARANCE OF THE SHEATH. ADDITIONAL TRACTION WAS APPLIED, WHICH RESULTED IN THE INNER LINING OF THE SHEATH BEING PULLED INWARD AND/OR STRIPPED. THIS LED TO THE ALLEGED DETACHMENT OF THE FUNNEL AND BASKETS FROM THE POUNCE SYSTEM. DEVICE COMPONENTS (STILL ENGAGED WITH THROMBUS) BECAME ENTRAPPED WITHIN THE VASCULATURE. DURING A FOLLOW-UP PHONE CALL, THE MANUFACTURER REPRESENTATIVE COULD NOT CONFIRM IF THE DEVICE BASKETS HAD SEPARATED FROM THE BASKET WIRE. A SURGICAL CUTDOWN OF THE LEFT COMMON FEMORAL AR

    Patient problems: Foreign Body In Patient

    MAUDE report 22476060 ↗

Other Peripheral Mechanical Thrombectomy With Aspiration devices

All Peripheral Mechanical Thrombectomy With Aspiration devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page