G-Probe™ Illuminate Box of 6 16000Recalls & reported problems
Iridex Corporation · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00813125015350), received between Feb 3, 2022 and Jun 18, 2022 — classified as 2 injuries.
The most frequently reported specific device problem is “Patient-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Appropriate Device Problem Term/Code Not Available1
- Patient-Device Incompatibility1
Patient problems
- Eye Burn1
- Superficial (First Degree) Burn1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJun 18, 2022Patient-Device Incompatibility
IRIDEX BECAME AWARE OF A COMPLAINT REPORTING A PATIENT EXPERIENCING MULTIPLE CONJUNCTIVAL BURNS DURING TREATMENT WITH THE G-PROBE. A SPECIFIC ROOT CAUSE COULD NOT BE DETERMINED. BASED ON SIMILAR REPORTED EVENTS, THE MOST LIKELY CAUSE OF THE ISSUE IS SUSPECTED TO BE CONTAMINATION (E.G. BLOOD, TISSUE OR BETADINE) ON THE PROBE TIP WHEN THE LASER WAS ACTIVATED OR LASER ACTIVATION WHEN THE PROBE IS OVER PIGMENTED CONJUNCTIVAL TISSUE. THE IS NO ADDITIONAL INFORMATION AVAILABLE AT THIS TIME. ENGINEERING FAILURE ANALYSIS WAS NOT PERFORMED BECAUSE THE DEVICE WAS NOT RETURNED FOR EVALUATION. THE G-PROBE IFU HAS CLEAR INSTRUCTIONS TO EXAMINE THE PROBE TIP BEFORE TREATMENT AND TO AVOID AREAS OF PERILIMBAL PIGMENTATION. PER THE IFU 'EXCESSIVE TREATMENT POWER MAY RESULT IN OCULAR SURFACE BURNS OR CILIARY BODY HEMORRHAGE. CONTAMINATION OF THE FIBER OPTIC TIP BY BLOOD OR TISSUE CHAR MAY RESULT IN OCULAR SURFACE BURNS. EXCESSIVE ENERGY MAY CAUSE EQUATORIAL BURNS. HEAVY PERILIMBAL CONJUNCTIVAL PIGMENTATION MAY RESULT IN LOCAL ABSORPTION AND BURNS; THEREFORE, AVOID AREAS OF HEAVY PERILIMBAL PIGMENTATION.' IF THE DEVICES ARE RETURNED AND THE RESULTS OF FAILURE ANALYSIS INDICATE NEW INFORMATION, THE AD
Patient problems: Eye Burn
MAUDE report 14740054 ↗InjuryFeb 3, 2022Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IRIDEX BECAME AWARE OF A COMPLAINT REPORTING 3 SCLERAL BURNS FOLLOWING TREATMENT WITH SLX LASER CONSOLE AND G-PROBE DELIVERY DEVICE. MINIMAL INFORMATION WAS PROVIDED BY THE CUSTOMER WITH RESPECT TO POTENTIAL CAUSES OF THE EVENTS OR THE PERFORMANCE OF THE LASER CONSOLE AND THE DELIVERY DEVICE. THE CUSTOMER CALL RECORD INDICATED THAT THE FOLLOWING TREATMENT PARAMETERS WERE USED 1250MW, 2000MS. NO OTHER INFORMATION WAS PROVIDED WITH THE CALL RECORD. THE DEVICES HAVE NOT BEEN RETURNED FOR EVALUATION. THE CUSTOMER HAS NOT RESPONDED TO REQUEST FOR ADDITIONAL INFORMATION. IRIDEX WILL CONTINUE TO FOLLOW UP AND ATTEMPT TO GET ADDITIONAL INFORMATION RELATED TO THE EVENT. AT THIS TIME, IT IS NOT POSSIBLE TO DETERMINE THE ROOT CAUSE OF THE ISSUE AND IT IS NOT KNOWN IF THE SCLERAL BURNS REPORTED AFFECTED A SINGLE PATIENT OR MULTIPLE PATIENTS. AN AMENDED REPORT WILL BE SUBMITTED IF ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: Superficial (First Degree) Burn
MAUDE report 13446775 ↗
Other Powered Laser Surgical Instrument devices
- Moxy 0010-2400Boston Scientific Corporation · Powered Laser Surgical Instrument4,572 reports
- SOLTIVE TFL-PLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls450 reports
- Flexiva TracTip M0068403960Boston Scientific Corporation · Powered laser surgical instrument562 reports
- Moses™ AC-10030100Lumenis Ltd. · Powered Laser Surgical Instrument532 reports
- Flexiva M0068403910Boston Scientific Corporation · Powered laser surgical instrument376 reports
- Visualase 9735542Medtronic Navigation, Inc. · Powered laser surgical instrument1 recall2 deaths311 reports
- SOLTIVE TFL-SLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls33 reports
- NeuroBlate® System 20980Monteris Medical Inc · Powered laser surgical instrument7 deaths296 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page