IQ532 Laser Console 65500Recalls & reported problems
Iridex Corporation · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00813125016258), received between Jan 26, 2026 and Jan 26, 2026 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Blurred Vision1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 26, 2026Adverse Event Without Identified Device or Use Problem
AN ADVERSE EVENT WAS REPORTED TO IRIDEX WHERE FIVE DAYS AFTER UNDERGOING TREATMENT FOR CENTRAL SEROUS RETINOPATHY USING THE IRIDEX LASER CONSOLE IQ532 WITH THE SLIT LAMP ADAPTER (SLA) AND THE SUBTHRESHOLD MICROPULSE LASER PHOTOCOAGULATION TECHNIQUE, A PATIENT EXPERIENCED WORSENED VISUAL ACUITY WITH A LARGE AREA OF COAGULATION AND SCOTOMA NOTED. IT SHOULD BE NOTED THAT THE PATIENT DEMONSTRATED IMPROVED VISUAL ACUITY IMMEDIATELY AFTER THE PROCEDURE WAS PERFORMED, WITH NO DEVICE MALFUNCTION NOR TREATMENT DEVIATION IMMEDIATELY FOLLOWING THE PROCEDURE. THE PHYSICIAN FURTHER REPORTED THAT THE PARAMETERS USED TO TREAT THE PATIENT WERE WITHIN THE RANGE AS DESCRIBED IN THE OPERATOR MANUAL OF THE DEVICE (300 MW MICROPULSE DUTY CYCLE, 300 MS DURATION, 145 INTERVALS, AND A TOTAL OF 102 LASER SHOTS ADMINISTERED USING A SINGLE-SHOT GRIS PATTERN). NO BLANCHING, COAGULATION, SUBCONJUNCTIVAL HEMORRHAGE, OR INTRAOPERATIVE BLEEDING WAS OBSERVED DURING EITHER THE TEST APPLICATIONS OR THE PRIMARY TREATMENT. NO PIGMENTED LESIONS OR AREAS OF INCREASED PIGMENTATION WERE PRESENT IN THE SURGICAL FIELD. AT THE ONE-WEEK POSTOPERATIVE VISIT, THE PATIENT'S VA HAD DECREASED TO 20/50, AND CLINICAL EXAMINATION REV
Patient problems: Blurred Vision
MAUDE report 24185371 ↗
Other Powered Laser Surgical Instrument devices
- Moxy 0010-2400Boston Scientific Corporation · Powered Laser Surgical Instrument4,572 reports
- SOLTIVE TFL-PLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls450 reports
- Flexiva TracTip M0068403960Boston Scientific Corporation · Powered laser surgical instrument562 reports
- Moses™ AC-10030100Lumenis Ltd. · Powered Laser Surgical Instrument532 reports
- Flexiva M0068403910Boston Scientific Corporation · Powered laser surgical instrument376 reports
- Visualase 9735542Medtronic Navigation, Inc. · Powered laser surgical instrument1 recall2 deaths311 reports
- SOLTIVE TFL-SLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls33 reports
- NeuroBlate® System 20980Monteris Medical Inc · Powered laser surgical instrument7 deaths296 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page