Clinical Innovations, LLC · Koala® Intrauterine Pressure Catheter with external balloon · Class 2

Adverse event reports
3
Deaths reported
1
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00814247020178), received between Feb 4, 2021 and Dec 31, 2024 — classified as 1 death, 2 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Insufficient Device Problem Information1

Patient problems

  • Head Injury1
  • Injury1
  • Laceration(s)1
  • Uterine Perforation1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • DeathDec 31, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    THE REPORTER STATED THE 27.6/7 GESTATION SUSTAIN 10.4 CM. LACERATION ALL THE WAY DOWN TO HER SKULL WHILE SHE IS IN HIS MOTHER'S WOMB. MOM HAD PREMATURE RUPTURE OF MEMBRANES AND ADMITTED TO THE HOSPITAL, AND SHE DEVELOPED CHORIO. THE ATTENDING OB PHYSICIAN ORDERED IUPC, MULTIPLE INSERTION ATTEMPTS BY THE RESIDENT AND A FELLOW FAILED. MOM'S VAGINA WAS COVERED WITH FRANK BLOOD. THE BABY WAS DELIVERED BY CAESAREAN SECTION AT 11:50 PM IN (B)(6) HOSPITAL BY EMERGENCY C-SECTION. THE BABY WAS ADMITTED ON (B)(6) 2022 AND EXPIRED ON (B)(6) 2022. THE AUTOPSY DIAGNOSIS WAS BACTERIAL MENINGITIS. THE BABY WITH SCALPED AT THE TIME OF DELIVERY. THE BABY WAS DELIVERED 2 HOURS LATER, AND THE LACERATION WAS DISCOVERED. THE ULTRASOUND CONFIRMED THE INJURY OCCURRED WHILE BABY IS IN HIS MOTHER'S WOMB.

    Patient problems: Head Injury; Laceration(s)

    MAUDE report 21048361 ↗
  • InjuryMay 2, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IN THE CUSTOMERS WORDS: "UTERINE RUPTURE AFTER USING IUPC FOR AMNIOINFUSION. IUPC PLACED AT 0254. AMNIOINFUSION STARTED AT 0905 300 ML BOLUS AT RATE OF 999ML/HR THEN 50 ML/HR. WAS STARTED APPROXIMATELY 90 MINUTES PRIOR TO IDENTIFICATION OF UTERINE RUPTURE. NO FLUID RETURNED FROM AMNIOINFUSION, ABDOMEN PALPATED SOFT BETWEEN CONTRACTIONS. URGENT C/S DUE TO CONCERN FOR UTERINE RUPTURE, EXHIBITED CHANGE IN SVE AND LOSS OF ABILITY TO FIND FHT WITH EXTERNAL AND INTERNAL MONITORS. SURGEON NOTED PLACENTAL FRAGMENTS AND FETAL HEAD PALPABLE EXTRAUTERINE CONSISTENT WITH UTERINE RUPTURE. THERAPY DURATION: 1.5 HOUR. UTERINE ACTIVITY, MEASUREMENT OF MVUS."

    Patient problems: Uterine Perforation

    MAUDE report 19230704 ↗
  • InjuryFeb 4, 2021Adverse Event Without Identified Device or Use Problem

    THE USER FACILITY REPORTED THE FOLLOWING: "WE HAVE BEEN USING THE IUPC'S FOR A COUPLE WEEKS NOW AND HAVE HAD A COUPLE INJURIES TO BABIES THAT ARE POTENTIALLY RELATED THE TO THE INSERTION OF THE KOALA IUPCS".

    Patient problems: Injury

    MAUDE report 11280027 ↗