Penumbra System PSC041Recalls & reported problems
Penumbra, Inc. · PS RP Catheter 041 · Class 2
All models of Penumbra System (59)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00814548010328), received between Sep 24, 2015 and Sep 25, 2015 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Insufficient Device Problem Information1
Patient problems
- Hemorrhage, Subarachnoid1
- Vasoconstriction1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 25, 2015Insufficient Device Problem Information
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE INTERNAL CAROTID ARTERY USING A PENUMBRA SYSTEM 041 REPERFUSION CATHETER (041 CATHETER). DURING THE PROCEDURE, ANOTHER MANUFACTURER'S RETRIEVER WAS INITIALLY USED FOR THROMBECTOMY IN THE INTERNAL CAROTID ARTERY AND REVASCULARIZATION WAS MADE. THE PHYSICIAN THEN IDENTIFIED SOME OCCLUDED PARTS BETWEEN THE DISTAL M1 TO M2; THEREFORE, THE RETRIEVER WAS USED AGAIN BUT THERE WAS NO REVASCULARIZATION. AS A SECOND DEVICE, A 041 CATHETER WAS ADVANCED TO THE TARGET VESSEL, AND BLEEDING WAS CONFIRMED AT THE PRE ASPIRATION ANGIOGRAPHY. A BALLOON CATHETER WAS USED THEN USED FOR HEMOSTASIS AND BLEEDING WAS RESOLVED. THE PATIENTS' CONDITION DID NOT MAKE ANY CHANGE AT THAT TIME. A VERY MINOR SUBARACHNOID HEMORRHAGE (SAH) WAS FOUND. THE PATIENTS' STROKE WORSENED WHICH LED TO THE PATIENTS' DEATH THE FOLLOWING MONTH. PHYSICIAN'S COMMENT: NORMAL LOGIC WOULD BE THAT BLEEDING WAS HIGHLY LIKELY TO BE CAUSED BY THE USE OF ANOTHER MANUFACTURERS RETRIEVER AROUND THE ANEURYSM. EQUALLY, THERE ARE HIGH CHANCES THAT EITHER THE MICRO CATHETER OR THE MICRO GUIDE WIRE HAS PERFORATED. SAH WAS MINOR ENOUGH NOT TO BE THE REASON OF DEATH, BUT WORSENING OF STRO
Patient problems: Hemorrhage, Subarachnoid
MAUDE report 5104558 ↗InjurySep 24, 2015Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE INTERNAL CAROTID ARTERY (ICA) USING A PENUMBRA SYSTEM 5MAX REPERFUSION CATHETER (5MAX), A PENUMBRA SYSTEM 3MAX REPERFUSION CATHETER (3MAX), A PENUMBRA SEPARATOR FLEX 054, A PENUMBRA SYSTEM 4MAX SEPARATOR AND A PENUMBRA SYSTEM REPERFUSION CATHETER 041. DURING THE PROCEDURE, THE PATIENT EXPERIENCED VASOSPASM OF THE RIGHT CERVICAL ICA; HOWEVER, THE PROCEDURE COMPLETED SUCCESSFULLY. THERE IS A PROBABLE RELATIONSHIP BETWEEN THE PENUMBRA DEVICES AND THE VASOSPASM HOWEVER THERE IS A DEFINITE RELATIONSHIP BETWEEN THE VASOSPASM AND THE ANGIOGRAPHIC PROCEDURE. POST PROCEDURAL ANALYSIS SHOWED NO EVIDENCE OF COMPLICATIONS TO THE PATIENT.
Patient problems: Vasoconstriction
MAUDE report 5102106 ↗
FDA clearance and classification
Cleared through Special 510(k) K100769 on May 21, 2010 (decision: Substantially Equivalent). Submitted by Penumbra, Inc. as “Penumbra System Separator Flex (026,032,041,054), Models Psf026, Psf032, Psf041, Psf054”. The FDA review took 64 days. FDA record ↗
The FDA regulates product code NRY (catheter, thrombus retriever) under 21 CFR 870.1250 as a Class II device. 21 CFR 870.1250 ↗
FDA definition of this device type: The device is intended to restore blood flow by removing thrombus/clots in patients experiencing ischemic stroke. The prior clearances in this category have been limited to simply identifying catheter placed in the peripheral, coronary, and neurovasculature. It is felt that this is a unique claim and should not be combined with previously cleared catheters under a general procode.
Common questions about the Penumbra System PSC041
Has the Penumbra System PSC041 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00814548010328), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Penumbra System PSC041?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between Sep 24, 2015 and Sep 25, 2015. In those reports, the most common patient problems are “Hemorrhage, Subarachnoid” (1) and “Vasoconstriction” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Penumbra System PSC041?
None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Penumbra System PSC041 FDA approved?
It was cleared through Special 510(k) K100769 on May 21, 2010. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the Penumbra System PSC041, and is it still sold?
The FDA's device database lists Penumbra, Inc. as the company responsible for it (brand Penumbra System, model PSC041). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other CATHETER, THROMBUS RETRIEVER devices
- Penumbra System 5MAXJET7KIT-BPenumbra, Inc. · Catheter, Thrombus Retriever1 recall14 deaths221 reports
- Penumbra System 3MAXCPenumbra, Inc. · CATHETER, THROMBUS RETRIEVER1 death241 reports
- EMBOTRAP ET309537Neuravi Limited · Catheter, Thrombus Retriever13 deaths177 reports
- ACE 5MAXACE068KITPenumbra, Inc. · CATHETER, THROMBUS RETRIEVER170 reports
- Embotrap ET009533Neuravi Limited · Catheter, Thrombus Retriever16 deaths153 reports
- Penumbra System 5MAXACE132Penumbra, Inc. · CATHETER, THROMBUS RETRIEVER3 deaths112 reports
- Penumbra System 5MAXJET7KIT-APenumbra, Inc. · Catheter, Thrombus Retriever1 death94 reports
- Trevo XP 90185Stryker Corporation · CATHETER, THROMBUS RETRIEVER1 recall1 death40 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page