Penumbra System PSF041Recalls & reported problems
Penumbra, Inc. · PS Separator Flex 041 · Class 2
All models of Penumbra System (59)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 1
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00814548010427), received between Sep 24, 2015 and Oct 7, 2016 — classified as 1 death, 4 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Device Operates Differently Than Expected” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem5
- Device Operates Differently Than Expected2
Patient problems
- Hemorrhage, Subarachnoid3
- Vasoconstriction3
- Hemorrhage, Cerebral2
- No Consequences Or Impact To Patient2
- Death, Intrauterine Fetal1
- Extravasation1
- Intracranial Hemorrhage1
- Perforation of Vessels1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
DeathOct 7, 2016Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE FOR A CARDIOGENIC CEREBRAL INFARCTION IN THE LEFT MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SYSTEM 5MAX ACE REPERFUSION CATHETER (5MAX ACE), A PENUMBRA SYSTEM 5MAX SEPARATOR (5MAX SEPARATOR), A PENUMBRA SYSTEM 4MAX REPERFUSION CATHETER (4MAX) AND A PENUMBRA SYSTEM 4MAX SEPARATOR (4MAX SEPARATOR). DURING THE PROCEDURE, THE PHYSICIAN ATTEMPTED TO ASPIRATE THE THROMBUS USING THE 5MAX ACE AND 5MAX SEPARATOR BUT WAS UNSUCCESSFUL BECAUSE THE THROMBUS WAS TOO STIFF. THEREFORE, THE PHYSICIAN DECIDED TO USE ANOTHER MANUFACTURER'S RETRIEVAL DEVICE TO REMOVE THE THROMBUS; HOWEVER, WHILE USING THE RETRIEVAL DEVICE, THE PHYSICIAN NOTICED THAT A PIECE OF THE THROMBUS MIGRATED TO THE DISTAL M2 SEGMENT OF THE MCA. THE PHYSICIAN THEN SWITCHED TO THE 4MAX AND 4MAX SEPARATOR TO REMOVE THE THROMBUS IN THE M2 SEGMENT. THE PROCEDURE WAS COMPLETED AND THE PHYSICIAN WAS ABLE TO REMOVE ALL THE THROMBUS FROM THE PATIENT. THERE WERE NO ALLEGED MALFUNCTIONS WITH THE PENUMBRA DEVICES. FOLLOWING THE PROCEDURE, THE PATIENT'S THROMBOLYSIS IN CEREBRAL INFARCTION (TICI) GRADE IMPROVED FROM A ZERO TO A THREE, INDICATING COMPLETE PERFUSION. HOWEVER, WITHIN TWENT
Patient problems: Death, Intrauterine Fetal; Intracranial Hemorrhage
MAUDE report 6011845 ↗MalfunctionJun 14, 2016Device Operates Differently Than Expected; Device Operates Differently Than Expected
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE LEFT MIDDLE CEREBRAL ARTERY (MCA) FOR A CEREBRAL INFARCTION USING A PENUMBRA SYSTEM 4MAX SEPARATOR (SEP4). DURING THE PROCEDURE, THE PHYSICIAN FIRST USED ANOTHER MANUFACTURER'S THROMBECTOMY DEVICE AND THEN SWITCHED TO THE PENUMBRA DEVICES. THE SEP4 WAS INSERTED INTO A PENUMBRA SYSTEM 4MAX REPERFUSION CATHETER (4MAX) AND THEN A TORQUE DEVICE WAS ATTACHED TO THE SEP4. HOWEVER, UPON ATTEMPTING TO CHANGE THE POSITION OF THE TORQUE DEVICE, THE PHYSICIAN NOTICED THAT IT WAS STUCK AND UNABLE TO BE REMOVED FROM THE SEP4. THEREFORE, THE PHYSICIAN REMOVED THE SEP4 AND OPENED A NEW SEP4 AND TORQUE DEVICE FOR THE PROCEDURE. HOWEVER, THE NEW TORQUE DEVICE ALSO BECAME STUCK AND UNABLE TO BE REMOVED FROM THE SEP4. THEREFORE, THE SEP4 WAS REMOVED AND THE PROCEDURE WAS COMPLETED USING THE FIRST THROMBECTOMY DEVICE FROM THE OTHER MANUFACTURER. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 5724757 ↗MalfunctionJun 14, 2016Device Operates Differently Than Expected; Device Operates Differently Than Expected
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE LEFT MIDDLE CEREBRAL ARTERY (MCA) FOR A CEREBRAL INFARCTION USING A PENUMBRA SYSTEM 4MAX SEPARATOR (SEP4). DURING THE PROCEDURE, THE PHYSICIAN FIRST USED ANOTHER MANUFACTURER'S THROMBECTOMY DEVICE AND THEN SWITCHED TO THE PENUMBRA DEVICES. THE SEP4 WAS INSERTED INTO A PENUMBRA SYSTEM 4MAX REPERFUSION CATHETER (4MAX) AND THEN A TORQUE DEVICE WAS ATTACHED TO THE SEP4. HOWEVER, UPON ATTEMPTING TO CHANGE THE POSITION OF THE TORQUE DEVICE, THE PHYSICIAN NOTICED THAT IT WAS STUCK AND UNABLE TO BE REMOVED FROM THE SEP4. THEREFORE, THE PHYSICIAN REMOVED THE SEP4 AND OPENED A NEW SEP4 AND TORQUE DEVICE FOR THE PROCEDURE. HOWEVER, THE NEW TORQUE DEVICE ALSO BECAME STUCK AND UNABLE TO BE REMOVED FROM THE SEP4. THEREFORE, THE SEP4 WAS REMOVED AND THE PROCEDURE WAS COMPLETED USING THE FIRST THROMBECTOMY DEVICE FROM THE OTHER MANUFACTURER. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 5724749 ↗InjuryApr 28, 2016Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON (B)(6) 2013, THE PATIENT UNDERWENT A THROMBECTOMY PROCEDURE IN THE MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SYSTEM 5MAX SEPARATOR (SEP5), A PENUMBRA SYSTEM 5MAX REPERFUSION CATHETER (5MAX), A VELOCITY DELIVERY MICROCATHETER (VELOCITY) AND A PENUMBRA SYSTEM 4MAX SEPARATOR (SEP4). PRIOR TO THE PROCEDURE, THE PATIENT WAS GIVEN FOUR UNITS OF FRESH FROZEN PLASMA (FFP). ON THE FINAL RUN, EXTRAVASATION AT THE MCA BIFURCATION WAS NOTED AND SO 50 MG OF PROTAMINE WAS GIVEN TO REVERSE HEPARIN. THE TARGET VESSEL WAS RECANALIZED; HOWEVER, A VESSEL PERFORATION WAS IDENTIFIED, WHICH WAS RELATED TO THE DEVICES USED. A FOLLOW-UP DYNA COMPUTERIZED TOMOGRAPHY (CT) WAS PERFORMED AND REVEALED A SYLVIAN SUBARACHNOID HEMORRHAGE (SAH) AND INTRAVENTRICULAR HEMORRHAGE (IVH) IN THE FOURTH VENTRICLE. ABOUT SIX HOURS LATER, A NONCONTRAST COMPUTERIZED TOMOGRAPHY (NCCT) WAS PERFORMED AND SHOWED EVIDENCE OF SAH BUT THE IVH WAS NOT VISIBLE ANYMORE. ON POST-OPERATIVE DAY 1 ((B)(6) 2013), AN NCCT WAS PERFORMED AND STILL SHOWED THE SAH. ON POST-OPERATIVE DAY 2 ((B)(6) 2013), ANOTHER NCCT WAS PERFORMED AND SHOWED A SLIGHT HEMORRHAGIC TRANSFORMATION IN THE RIGHT CAUDATE NUCLEUS AND ONLY SLIGHT RESIDUAL SUBARACH
Patient problems: Extravasation; Hemorrhage, Subarachnoid; Perforation of Vessels
MAUDE report 5615379 ↗InjuryOct 8, 2015Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE MIDDLE CEREBRAL ARTERY (MCA) USING PENUMBRA SYSTEM 3MAX REPERFUSION CATHETERS, PENUMBRA SYSTEM 3MAX SEPARATORS, PENUMBRA SYSTEM 4MAX REPERFUSION CATHETERS, AND PENUMBRA SYSTEM 4MAX SEPARATORS. DURING THE PROCEDURE THE PATIENT EXPERIENCED A MILD VASOSPASM AT THE RIGHT MCA AND RIGHT INTERNAL CAROTID ARTERY; HOWEVER THE PROCEDURE WAS COMPLETED SUCCESSFULLY. 24 HOURS POST-PROCEDURE A NON-CONTRAST COMPUTERIZED TOMOGRAPHY (NCCT) OF THE HEAD REVEALED A SUBARACHNOID HEMORRHAGE (SAH); HOWEVER, A MAGNETIC RESONANCE IMAGING (MRI) PERFORMED 3 DAYS POST PROCEDURE REVEALED AN INTRACEREBRAL HEMORRHAGE (ICH; HI-1) AND NO SAH. THE PATIENT IMPROVED CLINICALLY SEVERAL DAYS POST PROCEDURE AND WAS DISCHARGED. THE COMMITTEE REVIEWED THE EVENT AND ADJUDICATED VASOSPASM AS A NON-SERIOUS ADVERSE EVENT, PROBABLY RELATED TO THE PENUMBRA SYSTEM, DEFINITELY RELATED TO THE ANGIOGRAPHIC PROCEDURE, UNRELATED TO IVTPA, AND UNRELATED TO THE INDEX STROKE. THE COMMITTEE ADJUDICATED SAH AS A SERIOUS ADVERSE EVENT, POSSIBLY RELATED TO THE PENUMBRA SYSTEM, POSSIBLY RELATED TO THE ANGIOGRAPHIC PROCEDURE, UNRELATED TO THE INDEX STROKE AND OF UNCERTAIN RELATIONSHIP
Patient problems: Hemorrhage, Cerebral; Hemorrhage, Subarachnoid; Vasoconstriction
MAUDE report 5138659 ↗InjuryOct 8, 2015Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE MIDDLE CEREBRAL ARTERY (MCA) USING PENUMBRA SYSTEM 3MAX REPERFUSION CATHETERS, PENUMBRA SYSTEM 3MAX SEPARATORS, PENUMBRA SYSTEM 4MAX REPERFUSION CATHETERS, AND PENUMBRA SYSTEM 4MAX SEPARATORS. DURING THE PROCEDURE THE PATIENT EXPERIENCED A MILD VASOSPASM AT THE RIGHT MCA AND RIGHT INTERNAL CAROTID ARTERY; HOWEVER THE PROCEDURE WAS COMPLETED SUCCESSFULLY. 24 HOURS POST-PROCEDURE A NON-CONTRAST COMPUTERIZED TOMOGRAPHY (NCCT) OF THE HEAD REVEALED A SUBARACHNOID HEMORRHAGE (SAH); HOWEVER, A MAGNETIC RESONANCE IMAGING (MRI) PERFORMED 3 DAYS POST PROCEDURE REVEALED AN INTRACEREBRAL HEMORRHAGE (ICH; HI-1) AND NO SAH. THE PATIENT IMPROVED CLINICALLY SEVERAL DAYS POST PROCEDURE AND WAS DISCHARGED. THE COMMITTEE REVIEWED THE EVENT AND ADJUDICATED VASOSPASM AS A NON-SERIOUS ADVERSE EVENT, PROBABLY RELATED TO THE PENUMBRA SYSTEM, DEFINITELY RELATED TO THE ANGIOGRAPHIC PROCEDURE, UNRELATED TO IVTPA, AND UNRELATED TO THE INDEX STROKE. THE COMMITTEE ADJUDICATED SAH AS A SERIOUS ADVERSE EVENT, POSSIBLY RELATED TO THE PENUMBRA SYSTEM, POSSIBLY RELATED TO THE ANGIOGRAPHIC PROCEDURE, UNRELATED TO THE INDEX STROKE AND OF UNCERTAIN RELATIONSHIP
Patient problems: Hemorrhage, Cerebral; Hemorrhage, Subarachnoid; Vasoconstriction
MAUDE report 5138649 ↗InjurySep 24, 2015Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE INTERNAL CAROTID ARTERY (ICA) USING A PENUMBRA SYSTEM 5MAX REPERFUSION CATHETER (5MAX), A PENUMBRA SYSTEM 3MAX REPERFUSION CATHETER (3MAX), A PENUMBRA SEPARATOR FLEX 054, A PENUMBRA SYSTEM 4MAX SEPARATOR AND A PENUMBRA SYSTEM REPERFUSION CATHETER 041. DURING THE PROCEDURE, THE PATIENT EXPERIENCED VASOSPASM OF THE RIGHT CERVICAL ICA; HOWEVER, THE PROCEDURE COMPLETED SUCCESSFULLY. THERE IS A PROBABLE RELATIONSHIP BETWEEN THE PENUMBRA DEVICES AND THE VASOSPASM HOWEVER THERE IS A DEFINITE RELATIONSHIP BETWEEN THE VASOSPASM AND THE ANGIOGRAPHIC PROCEDURE. POST PROCEDURAL ANALYSIS SHOWED NO EVIDENCE OF COMPLICATIONS TO THE PATIENT.
Patient problems: Vasoconstriction
MAUDE report 5102102 ↗
FDA clearance and classification
Cleared through Special 510(k) K100769 on May 21, 2010 (decision: Substantially Equivalent). Submitted by Penumbra, Inc. as “Penumbra System Separator Flex (026,032,041,054), Models Psf026, Psf032, Psf041, Psf054”. The FDA review took 64 days. FDA record ↗
The FDA regulates product code NRY (catheter, thrombus retriever) under 21 CFR 870.1250 as a Class II device. 21 CFR 870.1250 ↗
FDA definition of this device type: The device is intended to restore blood flow by removing thrombus/clots in patients experiencing ischemic stroke. The prior clearances in this category have been limited to simply identifying catheter placed in the peripheral, coronary, and neurovasculature. It is felt that this is a unique claim and should not be combined with previously cleared catheters under a general procode.
Common questions about the Penumbra System PSF041
Has the Penumbra System PSF041 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00814548010427), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Penumbra System PSF041?
The FDA's MAUDE database lists 7 adverse event reports for this device, received between Sep 24, 2015 and Oct 7, 2016. In those reports, the most common specific device problem is “Device Operates Differently Than Expected” (2); the most common patient problems are “Hemorrhage, Subarachnoid” (3), “Vasoconstriction” (3) and “Hemorrhage, Cerebral” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Penumbra System PSF041?
1 report is classified as a death, 4 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Penumbra System PSF041 FDA approved?
It was cleared through Special 510(k) K100769 on May 21, 2010. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the Penumbra System PSF041, and is it still sold?
The FDA's device database lists Penumbra, Inc. as the company responsible for it (brand Penumbra System, model PSF041). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other CATHETER, THROMBUS RETRIEVER devices
- Penumbra System 5MAXJET7KIT-BPenumbra, Inc. · Catheter, Thrombus Retriever1 recall14 deaths221 reports
- Penumbra System 3MAXCPenumbra, Inc. · CATHETER, THROMBUS RETRIEVER1 death241 reports
- EMBOTRAP ET309537Neuravi Limited · Catheter, Thrombus Retriever13 deaths177 reports
- ACE 5MAXACE068KITPenumbra, Inc. · CATHETER, THROMBUS RETRIEVER170 reports
- Embotrap ET009533Neuravi Limited · Catheter, Thrombus Retriever16 deaths153 reports
- Penumbra System 5MAXACE132Penumbra, Inc. · CATHETER, THROMBUS RETRIEVER3 deaths112 reports
- Penumbra System 5MAXJET7KIT-APenumbra, Inc. · Catheter, Thrombus Retriever1 death94 reports
- Trevo XP 90185Stryker Corporation · CATHETER, THROMBUS RETRIEVER1 recall1 death40 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page