PX SLIM Delivery Microcatheter PXSLIMSTRRecalls & reported problems
Penumbra, Inc. · AdvPX400 STR 150DualMB · Class 2
All models of PX SLIM Delivery Microcatheter (9)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00814548012506), received between Oct 10, 2015 and Apr 27, 2016 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Hemorrhage, Subarachnoid1
- Perforation of Vessels1
- Vasoconstriction1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryApr 27, 2016Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT UNDERWENT A THROMBECTOMY PROCEDURE USING A PENUMBRA SYSTEM 5MAX REPERFUSION CATHETER, A PENUMBRA SYSTEM 3MAX REPERFUSION CATHETER, A PENUMBRA SYSTEM 3MAX SEPARATOR, A PX SLIM DELIVERY MICROCATHETER, A NEURON 6F SELECT CATHETER AND A NEURON MAX 6F 088 LONG SHEATH. ON POST-OPERATIVE DAY 1 AND DAY 3, A NON-CONTRAST COMPUTERIZED TOMOGRAPHY (NCCT) WAS PERFORMED AND REVEALED EVIDENCE OF A SUBARACHNOID HEMORRHAGE (SAH) IN THE DORSAL INSULA AND HEMORRHAGIC TRANSFORMATION. THE SAH WAS NOTED TO BE DUE TO VESSEL PERFORATION. THE PATIENT SHOWED OVERALL CLINICAL IMPROVEMENT IN NEUROLOGICAL STATUS AND WAS MAINTAINED ON DILTIAZEM AND ATENOLOL FOR ATRIAL FIBRILLATION THROUGHOUT THE HOSPITAL STAY. ON (B)(6) 2012, THE PATIENT WAS SUBSEQUENTLY DISCHARGED TO AN ACUTE REHABILITATION NURSING FACILITY. THE SAH WAS REVIEWED AND ADJUDICATED BY THE COMMITTEE TO BE A NON-SERIOUS ADVERSE EVENT WITH A POSSIBLE RELATIONSHIP TO THE PENUMBRA SYSTEM AND ANGIOGRAPHIC PROCEDURE BUT UNRELATED TO THE INDEX STOKE.
Patient problems: Hemorrhage, Subarachnoid; Perforation of Vessels
MAUDE report 5612053 ↗InjuryOct 10, 2015Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SYSTEM 5MAX ACE REPERFUSION CATHETER AND A PX SLIM DELIVERY MICROCATHETER. THE PROCEDURE WAS SUCCESSFUL AND COMPLETE VASCULARIZATION WAS RESTORED; NO PROCEDURAL COMPLICATIONS WERE REPORTED. HOWEVER, A SHORT LENGTH HIGHER GRADE STENOSIS AT THE ORIGIN OF THE HEFTY M2 BRANCH (VASOSPASM VS. DISSECTION) WAS NOTED ON THE POST-PENUMBRA SYSTEM ANGIOGRAM. THE COMMITTEE REVIEWED THE EVENT AND DETERMINED THAT THERE WAS A PRESENCE OF VASOSPASM. THE COMMITTEE ADJUDICATED VASOSPASM AS A NON-SERIOUS ADVERSE EVENT WITH A PROBABLE RELATIONSHIP TO THE PENUMBRA SYSTEM, PROBABLE RELATIONSHIP TO THE ANGIOGRAPHIC PROCEDURE, AND TO BE UNRELATED TO IVTPA AND TO THE INDEX STROKE.
Patient problems: Vasoconstriction
MAUDE report 5142421 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page