TriMAX Implant System TriMAX 18mm Full Prep KitRecalls & reported problems
Crossroads Extremity Systems · The TriMAX Implant System is a Nitinol Superelastic bone staple for use in surgery of the hand and foot for bone fragment osteotomy fixation and joint arthrodesis. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00815432027590), received between Sep 29, 2022 and Sep 29, 2022 — classified as 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Fracture1
- Migration1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 29, 2022Fracture; Migration; Fracture; Migration
THE SURGEON PERFORMED AN ISOLATED TN FUSION ON (B)(6) 2020. THE PATIENT WAS FUSED, AND DEVICES WERE INTACT AT 60 DAYS POST-OP. AT 85 DAYS POST-OP, THE X-RAY REVEALS THAT THE KEEL ON THE KEEL-LOCK STAPLE HAS BROKEN AND THE STAPLE HAS BACKED OUT OF THE BONE. THE PATIENT WAS WEIGHT-BEARING IN A CAM BOOT 1 WEEK PRIOR TO OBSERVATION OF THE BROKEN STAPLE. FUSION REMAINS INTACT DESPITE THE BACK-OUT OF THE STAPLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15501549 ↗
Other Staple, Fixation, Bone devices
- N/A StandardSynthes GmbH · Staple, Fixation, Bone2 recalls16 reports
- GII QUICKANCHOR ETHIBOND 212034Medos International Sàrl · STAPLE, FIXATION, BONE98 reports
- GII QUICKANCHOR ORTHOCORD 222983Medos International Sàrl · STAPLE, FIXATION, BONE94 reports
- Speed SE-0910Synthes GmbH · Staple, Fixation, Bone1 recall24 reports
- Speed Shift SE-2020-10Synthes GmbH · Staple, Fixation, Bone1 recall10 reports
- Lapiplasty SpeedPlate SK50Treace Medical Concepts, Inc. · Staple, Fixation, Bone59 reports
- Speed SE-1512Synthes GmbH · Staple, Fixation, Bone1 recall6 reports
- LUPINE ORTHOCORD 210709Depuy Mitek, LLC · STAPLE, FIXATION, BONE56 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page