Penumbra, Inc. · Aspiration Catheter 8, 85cm TORQ Kit · Class 2

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00815948022294), received between Nov 2, 2021 and Jan 8, 2024 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Fracture1
  • Physical Resistance/Sticking1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 8, 2024Fracture; Physical Resistance/Sticking; Fracture; Physical Resistance/Sticking

    THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE RIGHT SUPERFICIAL FEMORAL ARTERY (SFA) USING AN INDIGO SYSTEM ASPIRATION CATHETER 8 (CAT8), AN INDIGO SYSTEM SEPARATOR 8 (SEP8), A GUIDING SHEATH, A STENT, AND A GUIDEWIRE. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED THE CAT8 AND SEP8 INTO THE TARGET VESSEL USING THE GUIDING SHEATH AND INITIATED ASPIRATION. IT WAS REPORTED THAT THE PHYSICIAN EXPERIENCED RESISTANCE WHILE ADVANCING THE CAT8 INTO THE GUIDING SHEATH. THE CAT8 WAS THEN TORQUED TO PERFORM ASPIRATION OVER A WIDE AREA. AFTER PULLING ON THE HUB OF THE CAT8 APPROXIMATELY 2-3 CENTIMETERS, THE PHYSICIAN NOTICED UNDER FLUOROSCOPY THAT THE DISTAL PART OF THE CAT8 DID NOT MOVE. UNDER FLUOROSCOPY THE PHYSICIAN CHECKED THE ILIAC BIFURCATION AND FOUND THAT THE MID-SHAFT OF THE CAT8 HAD FRACTURED AT THE BIFURCATION. THE PHYSICIAN THEN USED A BALLOON CATHETER TO HOLD THE CAT8 AND SEP8 IN PLACE INSIDE OF THE GUIDING SHEATH TO REMOVE THE DEVICES TOGETHER. THE PHYSICIAN ALSO ATTEMPTED TO INSERT THE GUIDEWIRE FOR ADDITIONAL SUPPORT, BUT THE GUIDEWIRE WOULD NOT ENTER THE FRACTURED SECTION OF THE CAT8. WHILE REMOVING, THE PHYSICIAN CUT ANOTHER SEGMENT OF THE CAT8 USING SCISSORS. TH

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18466129 ↗
  • MalfunctionNov 2, 2021Break; Break

    THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE SUPERFICIAL FEMORAL ARTERY (SFA) AND POPLITEAL ARTERY USING AN INDIGO SYSTEM ASPIRATION CATHETER 8 (CAT8) AND A GUIDEWIRE. DURING THE PROCEDURE, THE PHYSICIAN COMPLETED MULTIPLE PASSES IN THE TARGET VESSEL USING THE CAT8. WHILE TORQUING THE CAT8, THE PHYSICIAN FRACTURED THE CAT8 NEAR THE HUB, AND THE HUB OF THE CAT8 SEPARATED FROM THE CATHETER. THEREFORE, THE CAT8 WAS REMOVED. THE PROCEDURE WAS COMPLETED USING A NEW CAT8. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12741028 ↗

Other Peripheral Mechanical Thrombectomy With Aspiration devices