Lantern Delivery Catheter PXSLIMLAN160STRRecalls & reported problems
Penumbra, Inc. · PXSLIMLAN160STR · Class 2
All models of Lantern Delivery Catheter (11)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00815948023000), received between Jul 26, 2022 and Mar 23, 2024 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Fracture2
- Material Deformation1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 23, 2024Fracture; Fracture
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE FISTULA ARTERY USING A LANTERN DELIVERY MICROCATHETER (LANTERN), AND A NON-PENUMBRA GLIDE CATHETER. DURING THE PROCEDURE, WHILE MANIPULATING THE LANTERN INTO THE DESIRED LOCATION, THE LANTERN FRACTURED NEAR THE HUB. THEREFORE, THE LANTERN WAS REMOVED. THE PROCEDURE WAS COMPLETED USING A NEW LANTERN AND A NEW NON-PENUMBRA GLIDE CATHETER. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18965616 ↗MalfunctionDec 7, 2022Break; Break
THE PATIENT WAS UNDERGOING A MEDICAL PROCEDURE IN THE RIGHT PULMONARY ARTERIOVENOUS MALFORMATIONS (PAVM) USING A LANTERN DELIVERY MICROCATHETER (LANTERN) AND A GUIDEWIRE. DURING THE PROCEDURE, THE LANTERN WAS USED AND UPON REMOVAL THE LANTERN WAS NOTED TO BE BROKEN AT THE HUB. THEREFORE, THE LANTERN WAS NOT USED IN THE REMAINDER OF THE PROCEDURE. THE PROCEDURE WAS COMPLETED USING A NEW LANTERN. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15936627 ↗MalfunctionJul 26, 2022Break; Fracture; Material Deformation; Break; Fracture; Material Deformation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE ILIOLUMBAR ARTERY USING A LANTERN DELIVERY MICROCATHETER (LANTERN) AND A NEURON SELECT CATHETER 5F (5F SELECT). DURING THE PROCEDURE, WHILE ADVANCING THE LANTERN INTO THE 5F SELECT, THE PHYSICIAN KINKED AND FRACTURED THE MIDSHAFT OF THE LANTERN. THEREFORE, THE LANTERN WAS REMOVED. IT WAS ALSO REPORTED UPON INSPECTING THE LANTERN ON THE BACK TABLE, THE HOSPITAL TECHNOLOGIST BENT THE LANTERN AT THE LOCATION WHERE THE KINKED AND FRACTURED HAD OCCURRED. CONSEQUENTLY, THE HOSPITAL TECHNOLOGIST ENDED UP BREAKING THE LANTERN IN HALF. THE PROCEDURE WAS COMPLETED USING A NEW LANTERN AND THE SAME 5F SELECT. THERE WAS NO REPORT OF AN EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15104691 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page