Indigo System LITNGFXT100H1-ARecalls & reported problems
Penumbra, Inc. · CAT16 XTORQ 100cm, Select 135cm H1 Tip, Lightning Flash Tubing · Class 2
All models of Indigo System (64)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00815948024823), received between May 12, 2023 and Apr 5, 2024 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Fracture1
- Material Deformation1
- Physical Resistance/Sticking1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- Perforation of Vessels1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryApr 5, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE POPLITEAL VEIN USING AN INDIGO SYSTEM FLASH ASPIRATION CATHETER (FLASH CATHETER), AN INDIGO SYSTEM LIGHTNING FLASH ASPIRATION TUBING (FLASH TUBING), AN INDIGO SYSTEM ASPIRATION CATHETER 12 (CAT12), A PENUMBRA ENGINE (ENGINE) AND A NON-PENUMBRA SHEATH. IT WAS REPORTED THAT THE PATIENT HAD A DISTINCT ANATOMY WITH A DUPLICATED POPLITEAL VEIN. DURING THE PROCEDURE, THE PHYSICIAN ATTEMPTED TO ACCESS ONE OF THE DUPLICATED POPLITEAL VEINS WITH THE CAT12; HOWEVER, THE ACCESS WAS NOT SUCCESSFUL. THEREFORE, THE PHYSICIAN DECIDED TO RE-ACCESS THE LARGER POPLITEAL VEIN WITH THE FLASH CATHETER. AFTER ACCESS WAS GAINED WITH THE FLASH CATHETER, IT WAS NOTICED THAT THE FLASH TUBING WAS ILLUMINATING FLASHING RED LIGHT. THEREFORE, THE FLASH CATHETER AND THE FLASH TUBING WERE REMOVED. THE PHYSICIAN COMPLETED ONE PASS USING A NEW FLASH CATHETER OVER THE GUIDEWIRE. THE GUIDEWIRE WAS THEN REMOVED, AND THE PHYSICIAN DECIDED TO DO ONE MORE PASS WITHOUT THE GUIDEWIRE. WHEN THE FLASH CATHETER WAS ADVANCED FOR A SECOND PASS, A PERFORATION WAS NOTED FROM THE FEMORAL VEIN AT THE MID THIGH LEVEL. A FINAL VENOGRAM REVEALED THE PERFORATION HAD RESOLVED ON
Patient problems: Perforation of Vessels
MAUDE report 19055737 ↗MalfunctionMay 12, 2023Fracture; Material Deformation; Physical Resistance/Sticking; Fracture; Material Deformation; Physical Resistance/Sticking
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE BILATERAL ILIAC ARTERIES USING AN INDIGO SYSTEM FLASH ASPIRATION CATHETER, A NON-PENUMBRA SHEATH AND A GUIDEWIRE. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED THE FLASH CATHETER OVER THE GUIDEWIRE INTO THE STENTS. AFTER COMPLETING THREE PASSES USING THE FLASH CATHETER, THE FLASH CATHETER KEPT GETTING STUCK ON THE STENT FRAME. THEREFORE, THE FLASH CATHETER WAS REMOVED. UPON REMOVAL, THE PHYSICIAN INSPECTED THE FLASH CATHETER AND NOTICED THAT THE DISTAL END OF THE FLASH CATHETER WAS OVALIZED AND FRACTURED BUT IT WAS INTACT. THE PROCEDURE WAS COMPLETED USING A NEW FLASH CATHETER AND THE SAME SHEATH. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16925107 ↗
FDA clearance and classification
Cleared through 510(k) K222358 on Dec 20, 2022 (decision: Substantially Equivalent). Submitted by Penumbra, Inc. as “Indigo Aspiration System - Lightning Flash”. The FDA review took 138 days. FDA record ↗
The FDA regulates product code QEW (peripheral mechanical thrombectomy with aspiration) under 21 CFR 870.5150 as a Class II device. 21 CFR 870.5150 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Indigo System LITNGFXT100H1-A
Has the Indigo System LITNGFXT100H1-A been recalled?
No FDA recall record in our data names this exact device identifier (DI 00815948024823), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Indigo System LITNGFXT100H1-A?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between May 12, 2023 and Apr 5, 2024. In those reports, the most common specific device problems are “Fracture” (1), “Material Deformation” (1) and “Physical Resistance/Sticking” (1); the most common patient problem is “Perforation of Vessels” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Indigo System LITNGFXT100H1-A?
None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Indigo System LITNGFXT100H1-A FDA approved?
It was cleared through 510(k) K222358 on Dec 20, 2022. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the Indigo System LITNGFXT100H1-A, and is it still sold?
The FDA's device database lists Penumbra, Inc. as the company responsible for it (brand Indigo System, model LITNGFXT100H1-A). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Peripheral Mechanical Thrombectomy With Aspiration devices
- Indigo System LITNG12HTORQ115-APenumbra, Inc. · Peripheral Mechanical Thrombectomy With Aspiration4 deaths105 reports
- Indigo System LITNG7XTORQ130-APenumbra, Inc. · Peripheral mechanical thrombectomy with aspiration100 reports
- Indigo System LITNG12XTORQ100-APenumbra, Inc. · Peripheral Mechanical Thrombectomy With Aspiration1 death80 reports
- ClotTriever XL Catheter AS-0235Inari Medical, Inc. · Peripheral Mechanical Thrombectomy With Aspiration1 recall9 deaths21 reports
- Indigo System LITNGBT7TQ130-APenumbra, Inc. · Peripheral Mechanical Thrombectomy With Aspiration46 reports
- Indigo System LITNG12HTORQ100-APenumbra, Inc. · Peripheral Mechanical Thrombectomy With Aspiration1 death46 reports
- Triever 24 22-101Inari Medical, Inc. · Peripheral Mechanical Thrombectomy With Aspiration20 deaths34 reports
- ClotTriever Catheter, 16 mm 40-102Inari Medical, Inc. · Peripheral Mechanical Thrombectomy With Aspiration11 deaths27 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page