Skip to content

Benchmark MAX System BMX9690BER125-BRecalls & reported problems

Penumbra, Inc. · BMX96 90cm, STR Tip, 6F BER 125cm Select · Class 2

All models of Benchmark MAX System (13)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00815948026322), received between Oct 31, 2024 and Oct 31, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1
  • Physical Resistance/Sticking1
  • Stretched1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 31, 2024Fracture; Stretched; Physical Resistance/Sticking; Fracture; Stretched; Physical Resistance/Sticking

    THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE INTERNAL CAROTID ARTERY (ICA) AND THE M1 SEGMENT OF THE MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SYSTEM RED 43 REPERFUSION CATHETER (RED43), A PENUMBRA SYSTEM RED 72 REPERFUSION CATHETER (RED72), A BENCHMARK BMX96 ACCESS SYSTEM (BMX96), AND A NON-PENUMBRA SHEATH (8F). DURING THE PROCEDURE, THE RIGHT FEMORAL ARTERY WAS ACCESSED WITH THE SHEATH. THE PHYSICIAN ADVANCED A BMX96 AND RED72 TO THE TARGET LOCATION. IT WAS REPORTED THAT THE RED72 WAS UNABLE TO BE ADVANCED PAST THE CAVERNOUS SEGMENT OF THE ICA. THE PHYSICIAN THEN ADVANCED A RED43 THROUGH THE RED72 TO THE TARGET LOCATION. AFTER INITIATING ASPIRATION, THE DISTAL PORTION OF THE RED43 WAS NOTICED TO BE FRACTURED UNDER FLUOROSCOPY. THE FRACTURED SEGMENT OF THE RED43 WAS NOTICED TO BE AGAINST THE THROMBUS IN THE M1. THE PHYSICIAN REMOVED THE PROXIMAL SEGMENT OF THE RED43. NEXT, WHILE REMOVING THE RED72 FROM THE BMX96, THE PHYSICIAN NOTED RESISTANCE. THE PHYSICIAN THEN DECIDED TO REMOVE THE RED72 AND BMX96 TOGETHER FROM THE PATIENT, HOWEVER, RESISTANCE WAS ENCOUNTERED AND, SUBSEQUENTLY, THE RED72 AND BMX96 STRETCHED AND FRACTURED AT THE DISTAL LOCATION WITHIN THE SHEAT

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20582859 ↗

Other CATHETER, PERCUTANEOUS devices

All CATHETER, PERCUTANEOUS devices →

Sources and updates