Indigo System LITNGFHT115H1-DRecalls & reported problems

Penumbra, Inc. · CAT16 HTORQ 115cm, Select + 135cm H1 Tip, Lightning Flash 2.0 Tubing · Class 2

Adverse event reports
1
Deaths reported
1
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00815948029873), received between Apr 17, 2025 and Apr 17, 2025 — classified as 1 death.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Hemoptysis1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • DeathApr 17, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE TO TREAT AN ACUTE PULMONARY EMBOLISM IN THE LEFT PULMONARY ARTERY (LPA) AND RIGHT SEGMENTAL BRANCHES USING AN INDIGO SYSTEM LIGHTNING FLASH ASPIRATION TUBING (FLASH TUBING) AND AN INDIGO SYSTEM FLASH ASPIRATION CATHETER (FLASH CATHETER). IT WAS NOTED THAT THE PATIENT HAD A RIGHT VENTRICULAR (RV) STRAIN. DURING THE PROCEDURE, THE FLASH CATHETER WAS ADVANCED INTO THE LPA WITHOUT ISSUES AND ASPIRATION WAS INITIATED. AFTER APPROXIMATELY THREE MINUTES OF ASPIRATION, THE PATIENT BEGAN TO COUGH UP BLOOD AND THE PROCEDURE WAS ABORTED. THE PHYSICIAN THEN ADVANCED A BALLOON CATHETER TO STABILIZE THE PATIENT AND PERFORMED AN ANGIOGRAM. HOWEVER, THE PHYSICIAN COULD NOT FIND AN AREA OF PERFORATION. IT WAS REPORTED THAT THE PATIENT DEVELOPED AIRWAY OBSTRUCTION, AND CARDIOPULMONARY ARREST. RESUSCITATION EFFORTS THAT INCLUDED ADVANCED CARDIOVASCULAR LIFE SUPPORT (ACLS) INTERVENTION, CRICOTHYROTOMY, AND MECHANICAL VENTILATION WERE PERFORMED. THE PATIENT WAS ALSO ADMINISTERED PROTAMINE SULFATE, TWO UNITS OF FRESH RED BLOOD CELLS (PRBCS), AND TWO UNITS OF FRESH FROZEN PLASMA (FFP). THE PATIENT WAS ABLE TO REGAIN A STRONG PULSE FOR A SHORT TIME. AFTE

    Patient problems: Hemoptysis

    MAUDE report 21862567 ↗