Skip to content

Indigo System LITNGFHT100H1-DRecalls & reported problems

Penumbra, Inc. · CAT16 HTORQ 100cm, Select + 120cm H1 Tip, Lightning Flash 2.0 Tubing · Class 2

All models of Indigo System (64)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
1
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00815948029880), received between Jan 17, 2025 and Mar 24, 2026 — classified as 1 death, 3 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 2 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem4
  • Fracture1
  • Physical Resistance/Sticking1

Patient problems

  • Anemia2
  • No Clinical Signs, Symptoms or Conditions2
  • Hematoma1
  • Low Blood Pressure/ Hypotension1
  • Perforation of Vessels1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 24, 2026Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE PULMONARY ARTERY USING AN INDIGO SYSTEM FLASH ASPIRATION CATHETER (FLASH CATHETER), AN INDIGO SYSTEM LIGHTNING FLASH ASPIRATION TUBING (FLASH TUBING), AND AN ELEMENT VASCULAR ACCESS SHEATH (ELEMENT SHEATH). IT WAS REPORTED THAT DURING THE PROCEDURE, THE HEMOLOCK VALVE SYSTEM WAS LEAKING; HOWEVER, THE PHYSICIAN WAS ABLE TO COMPLETE THE PROCEDURE WITH THE SAME ELEMENT SHEATH. ON 24-FEB-2026, ADDITIONAL INFORMATION WAS RECEIVED FROM THE CLINICAL TEAM THAT POST-PROCEDURE, THERE WAS ACCESS SITE BLEEDING AND AN ECCHYMOSIS. TWO-DAYS POST PROCEDURE, THE HEMOGLOBIN DROPPED TO 7.8 G/DL. ONE UNIT OF PACKED RED BLOOD CELLS (PRBCS) WAS GIVEN. THE SITE REMAINED SOFT WITHOUT A HEMATOMA. ACUTE BLOOD LOSS ANEMIA WAS DETERMINED BY THE INDEPENDENT MEDICAL REVIEWER (IMR) TO BE A SERIOUS ADVERSE EVENT WITH A POSSIBLE RELATIONSHIP TO THE INDIGO ASPIRATION SYSTEM AND A DEFINITE RELATIONSHIP TO THE INDEX PROCEDURE. THE EVENT IS CONSIDERED RESOLVED.

    Patient problems: Anemia

    MAUDE report 24678799 ↗
  • MalfunctionMar 18, 2026

    WHILE PRIMING THE THROMBECTOMY DEVICE ON THE TABLE WE NOTICED THE DEVICES ELECTRONICS WAS DEFECTIVE. WE TRIED A FEW TIMES WITH THE SUPPORT OF THE REP FORM PENUMBRA TO TROUBLE SHOOT THE ERROR BUT NO LUCK. ITEM WAS NEVER USED ON PATIENTS. ITEM REMOVED FROM FIELD AND NEW PRODUCT OPENED ON FIELD THAT WORK WITHOUT ISSUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24626093 ↗
  • DeathFeb 6, 2026Adverse Event Without Identified Device or Use Problem

    THE PATIENT UNDERWENT A THROMBECTOMY PROCEDURE IN THE LEFT PULMONARY ARTERY USING AN INDIGO SYSTEM FLASH ASPIRATION CATHETER (FLASH CATHETER). FOLLOWING THE PROCEDURE, THE PATIENT EXPERIENCED DIFFICULTY BREATHING, HEMOPTYSIS, AND LARGE VOLUME BLOOD LOSS, WHICH REQUIRED ASPIRATION. THE PATIENT WAS INTUBATED INTO THE RIGHT BRONCHUS DUE TO THE INJURY IN THE LEFT LUNG. THE PATIENT LOST PULSES, PROMPTING THE EMERGENCY RESPONSE TEAM TO ADMINISTER CARDIOPULMONARY RESUSCITATION (CPR). IT WAS REPORTED BILATERAL GROIN ACCESS WAS ATTEMPTED FOR TRANSFUSION PROTOCOL. IT IS UNKNOWN IF ACCESS WAS SUCCESSFUL AND TRANSFUSION WAS PERFORMED. AFTER TWENTY MINUTES OF CPR, THE PATIENT EXPIRED. PERFORATION WAS REPORTED TO BE A SERIOUS ADVERSE EVENT WITH A DEFINITE RELATIONSHIP TO THE INDIGO ASPIRATION SYSTEM (FLASH CATHETER), AND A DEFINITE RELATIONSHIP TO THE INDEX PROCEDURE.

    Patient problems: Perforation of Vessels

    MAUDE report 24278582 ↗
  • InjuryApr 25, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ON (B)(6) 2024, THE PATIENT UNDERWENT A THROMBECTOMY PROCEDURE IN BILATERAL PULMONARY ARTERIES TO TREAT PULMONARY EMBOLISM (PE) USING AN INDIGO SYSTEM FLASH ASPIRATION CATHETER (FLASH CATHETER), CATHETER (6FR PIGTAIL), GUIDEWIRE (LONG J WIRE), AND SHEATHS (7FR AND 16FR) VIA THE RIGHT GROIN. DURING THE PROCEDURE, THE PIGTAIL CATHETER WAS ADVANCED AND BILATERAL PULMONARY ANGIOGRAMS WERE TAKEN. NEXT, THE 7FR SHEATH WAS UPSIZED TO THE 16FR SHEATH. MULTIPLE PASSES WERE COMPLETED WITH THE FLASH CATHETER IN THE TARGET LOCATIONS. POST ASPIRATION ANGIOGRAMS SHOWED SIGNIFICANT REDUCTION IN CLOT BILATERALLY. THE PROCEDURE WAS COMPLETED. THE SHEATH WAS REMOVED AND HEMOSTASIS WAS ACHIEVED WITH A FIGURE 8 SUTURE. IT WAS REPORTED THAT ON (B)(6) 2024, PURULENT FOUL-SMELLING DRAINAGE FROM THE RIGHT GROIN AT THE PREVIOUS VENOUS SHEATH SITE WAS NOTED WITH BLEEDING, BACTEREMIA WAS DIAGNOSED AND VANCOMYCIN WAS PRESCRIBED. ON (B)(6) 2024, THE PATIENT PRESENTED TO THE EMERGENCY DEPARTMENT (ED) DUE TO THE RIGHT GROIN WOUND WITH PURULENT DRAINAGE, NO BLOOD, NO ERYTHEMA, AND NON-TENDER. THE PATIENT WAS TREATED WITH ANTIBIOTICS AND DISCHARGED HOME. HEMATOMA WAS REPORTED TO BE AN ADVERSE EVENT WITH A PROBABLE

    Patient problems: Hematoma

    MAUDE report 21914013 ↗
  • InjuryMar 14, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE PULMONARY ARTERY USING AN INDIGO SYSTEM LIGHTNING FLASH ASPIRATION TUBING (FLASH TUBING), AN INDIGO SYSTEM FLASH ASPIRATION CATHETER (FLASH CATHETER), A NON-PENUMBRA FLUSH CATHETER (16FR), AND A NON-PENUMBRA FLOWTRIEVER SYSTEM. THE PROCEDURE WAS COMPLETED. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT. ON (B)(6) 2025, ONE DAY POST-PROCEDURE, IT WAS REPORTED THAT THE PATIENT DEVELOPED HYPOTENSION IN THE SETTING OF LOW HEMOGLOBIN (HGB). AT 9:58AM THE BLOOD PRESSURE WAS 113/70. AT 11:45AM THE BLOOD PRESSURE WAS 83/54. PRE-PROCEDURE, THE HGB WAS 12.1, ONE-DAY POST INDEX PROCEDURE, THE HGB WAS 8.0. TWO-DAY POST INDEX PROCEDURE, THE HGB WAS 8.0. A BLOOD TRANSFUSION WAS GIVEN. LOW BLOOD PRESSURE WAS DETERMINED BY THE INDEPENDENT MEDICAL REVIEWER (IMR) TO BE A SERIOUS ADVERSE EVENT WITH A POSSIBLE RELATIONSHIP TO THE INDIGO ASPIRATION SYSTEM AND A PROBABLE RELATIONSHIP TO THE INDEX PROCEDURE. THE EVENT WAS CONSIDERED TO BE RESOLVED WITH CLINICAL SEQUELAE ON (B)(6) 2024. LOW HEMOGLOBIN WAS DETERMINED BY THE IMR TO BE A SERIOUS ADVERSE EVENT WITH A POSSIBLE RELATIONSHIP TO THE INDIGO ASPIRATION SYSTEM AND A PROBABLE RELATIO

    Patient problems: Anemia; Low Blood Pressure/ Hypotension

    MAUDE report 21610833 ↗
  • MalfunctionJan 17, 2025Fracture; Physical Resistance/Sticking; Fracture; Physical Resistance/Sticking

    THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE POPLITEAL AND DISTAL FEMORAL VEIN USING AN INDIGO SYSTEM FLASH ASPIRATION CATHETER (FLASH CATHETER) AND A NON-PENUMBRA SHEATH. DURING THE PROCEDURE, WHILE MAKING THE FIRST PASS WITH THE FLASH CATHETER, THE PHYSICIAN FELT RESISTANCE. UNDER FLUOROSCOPY, THE FLASH CATHETER WAS NOTICED TO BE KINKED BETWEEN THE PROXIMAL AND MID-SHAFT. THE PHYSICIAN DECIDED TO REMOVE THE FLASH CATHETER. WHILE RETRACTING, THE FLASH CATHETER FRACTURED AT THE KINKED LOCATION; THEREFORE, THE PROXIMAL PORTION OF THE FLASH CATHETER WAS REMOVED. A SNARE DEVICE WAS ADVANCED TO REMOVE THE DISTAL PORTION OF THE FLASH CATHETER; HOWEVER, WHILE RETRACTING, THE SNARE LOST HOLD OF THE DISTAL SEGMENT. THEREFORE, THE REMAINING SEGMENT WAS REMOVED VIA CUTDOWN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21181706 ↗

FDA clearance and classification

Cleared through Special 510(k) K241399 on Jun 10, 2024 (decision: Substantially Equivalent). Submitted by Penumbra, Inc. as “Indigo® Lightning Flash Aspiration System – Select +™ Catheter”. The FDA review took 25 days. FDA record ↗

The FDA regulates product code QEW (peripheral mechanical thrombectomy with aspiration) under 21 CFR 870.5150 as a Class II device. 21 CFR 870.5150 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Indigo System LITNGFHT100H1-D

Has the Indigo System LITNGFHT100H1-D been recalled?

No FDA recall record in our data names this exact device identifier (DI 00815948029880), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Indigo System LITNGFHT100H1-D?

The FDA's MAUDE database lists 6 adverse event reports for this device, received between Jan 17, 2025 and Mar 24, 2026. In those reports, the most common specific device problems are “Fracture” (1) and “Physical Resistance/Sticking” (1); the most common patient problems are “Anemia” (2), “Hematoma” (1) and “Low Blood Pressure/ Hypotension” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Indigo System LITNGFHT100H1-D?

1 report is classified as a death, 3 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Indigo System LITNGFHT100H1-D FDA approved?

It was cleared through Special 510(k) K241399 on Jun 10, 2024. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Indigo System LITNGFHT100H1-D, and is it still sold?

The FDA's device database lists Penumbra, Inc. as the company responsible for it (brand Indigo System, model LITNGFHT100H1-D). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Peripheral Mechanical Thrombectomy With Aspiration devices

All Peripheral Mechanical Thrombectomy With Aspiration devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page