DB-400Recalls & reported problems
Laser Peripherals, LLC · 400u Bare Laser Fiber · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00816469020004), received between Oct 25, 2019 and Oct 25, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
1 other recall cover devices cleared under the same FDA submission (K030959); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 25, 2019Break
THE PT WAS HAVING A SURGICAL PROCEDURE DONE WHEN PART OF THE LASER FIBER BROKE OFF OF THE INSTRUMENT. THE SURGEON WAS ABLE TO RETRIEVE ALL PARTS AND NO HARM WAS NOTED TO THE PT. FDA SAFETY REPORT ID# (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9244812 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K030959. One submission often covers many models, so check the product and lot details in each record.
- Z-2073-2014 · Jun 20, 2014 · TerminatedLP,Surgical Fibers, Bare Laser Fiber 600 micron, DBLF-60-2, Sterile EO. Laser surgical instrument for use in general and plastic surgery and in dermatology
Other Powered laser surgical instrument devices
- Moxy 0010-2400Boston Scientific Corporation · Powered Laser Surgical Instrument4,572 reports
- SOLTIVE TFL-PLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls450 reports
- Flexiva TracTip M0068403960Boston Scientific Corporation · Powered laser surgical instrument562 reports
- Moses™ AC-10030100Lumenis Ltd. · Powered Laser Surgical Instrument532 reports
- Flexiva M0068403910Boston Scientific Corporation · Powered laser surgical instrument376 reports
- Visualase 9735542Medtronic Navigation, Inc. · Powered laser surgical instrument1 recall2 deaths311 reports
- SOLTIVE TFL-SLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls33 reports
- NeuroBlate® System 20980Monteris Medical Inc · Powered laser surgical instrument7 deaths296 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page