FullFire® Select Diffusing Tip Laser Probe 20624-4 (REF FFS422-01)Recalls & reported problems

Monteris Medical Inc · 2.2mm Diffusing Tip Laser Probe · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00816589020748), received between Mar 8, 2018 and Mar 8, 2018 — classified as 1 malfunction.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 8, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    BACKGROUND: MONTERIS MEDICAL ISSUED A SAFETY NOTIFICATION TO ALL NEUROBLATE USERS ON OCTOBER 5, 2017 IN ORDER TO MITIGATE A RISK OF CERTAIN MRI SYSTEMS THAT HAVE BEEN SHOWN TO INTERACT WITH THE NEUROBLATE PROBE AND CREATE UNINTENDED HEATING AT THE PROBE TIP. AMONG OTHER INFORMATION THE SAFETY NOTIFICATION PROVIDED INSTRUCTION TO UTILIZE CERTAIN MRI SCANS THAT WERE SHOWN TO PREVENT THE OCCURRENCE OF THE MALFUNCTION.IT WAS REPORTED IN THIS CASE THAT A HEALTH CARE PROFESSIONAL (HCP) PERFORMED AN MRI SCAN THAT WAS NOT CONSISTENT WITH INFORMATION PROVIDED PREVIOUSLY IN THE FORM OF A SAFETY ADVISORY NOTICE. AS WITH ALL NEUROBLATE PROCEDURES A MONTERIS EMPLOYEE WAS IN ATTENDANCE AT THE PROCEDURE IN A SUPPORT ROLE. DURING THE NEUROBLATE PROCEDURE THE MONTERIS EMPLOYEE NOTICED ANOMALOUS DATA IN THE PROBE THERMOCOUPLE READING AS REPORTED BY M-VISION SOFTWARE. THE MONTERIS EMPLOYEE THEN NOTICED THE INCORRECT MRI SCAN WAS BEING PERFORMED AND INSTRUCTED THE HCP TO STOP THE MRI SCAN. THE HCP THEN PROMPTLY STOPPED THE MRI SCAN. THESE EVENTS WERE REPORTED TO OCCUR OVER THE COURSE OF APPROXIMATELY 5 SECONDS. IT WAS NOTED THAT THE PROBE UMBILICALS WERE NOT CONTACTING THE MR BORE. THE PROBE WAS

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7325987 ↗

Other Powered Laser Surgical Instrument devices

All Powered Laser Surgical Instrument devices →