SideFire® Directional Laser Probe 20368-1Recalls & reported problems
Monteris Medical Inc · 3.3mm Directional Laser Probe · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00816589020779), received between Jul 2, 2018 and Jul 2, 2018 — classified as 1 malfunction.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 2, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
BACKGROUND: MONTERIS MEDICAL ISSUED A SAFETY NOTIFICATION TO ALL NEUROBLATE USERS ON (B)(6) 2017 IN ORDER TO MITIGATE A RISK OF CERTAIN MRI SYSTEMS THAT HAVE BEEN SHOWN TO INTERACT WITH THE NEUROBLATE PROBE AND CREATE UNINTENDED HEATING AT THE PROBE TIP. AMONG OTHER INFORMATION THE SAFETY NOTIFICATION PROVIDED INSTRUCTION TO UTILIZE CERTAIN MRI SCANS THAT WERE SHOWN TO PREVENT THE OCCURRENCE OF THE MALFUNCTION. IT WAS REPORTED IN THIS CASE THAT A HEALTH CARE PROFESSIONAL (HCP) PERFORMED AN MRI SCAN THAT WAS NOT CONSISTENT WITH INFORMATION PROVIDED PREVIOUSLY IN THE FORM OF A SAFETY ADVISORY NOTICE. AS WITH ALL NEUROBLATE PROCEDURES A MONTERIS EMPLOYEE WAS IN ATTENDANCE AT THE PROCEDURE IN A SUPPORT ROLE. DESPITE ADVISEMENT FROM THE MONTERIS MEDICAL EMPLOYEE SUPPORTING THE CASE THE TREATING HCP CHOOSE TO DEVIATE FROM THE INSTRUCTION PROVIDED IN PREVIOUS SAFETY ADVISORY NOTICES BY UTILIZING A T2 SCAN WITH THE PROBE IN THE PATIENT'S BRAIN. DURING THE T2 SCAN THE MONTERIS EMPLOYEE NOTICED ANOMALOUS DATA IN THE PROBE THERMOCOUPLE READING AS REPORTED BY M-VISION SOFTWARE. THE MONTERIS EMPLOYEE INSTRUCTED THE HCP TO STOP THE MRI SCAN. THE HCP THEN PROMPTLY STOPPED THE MRI SCAN. THESE EVEN
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7654498 ↗
Other Powered Laser Surgical Instrument devices
- Moxy 0010-2400Boston Scientific Corporation · Powered Laser Surgical Instrument4,572 reports
- SOLTIVE TFL-PLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls450 reports
- Flexiva TracTip M0068403960Boston Scientific Corporation · Powered laser surgical instrument562 reports
- Moses™ AC-10030100Lumenis Ltd. · Powered Laser Surgical Instrument532 reports
- Flexiva M0068403910Boston Scientific Corporation · Powered laser surgical instrument376 reports
- Visualase 9735542Medtronic Navigation, Inc. · Powered laser surgical instrument1 recall2 deaths311 reports
- SOLTIVE TFL-SLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls33 reports
- NeuroBlate® System 20980Monteris Medical Inc · Powered laser surgical instrument7 deaths296 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page