LVIS 212928-LVIS-D-HDERecalls & reported problems

Microvention, Inc. · Stent · Class f · Implant

All models of LVIS (17)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00816777026019), received between Oct 28, 2024 and Sep 11, 2025 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Activation Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Activation Failure1
  • Adverse Event Without Identified Device or Use Problem1
  • Retraction Problem1

Patient problems

  • Extravasation1
  • No Clinical Signs, Symptoms or Conditions1
  • Thrombosis/Thrombus1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjurySep 11, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SEE H11.

    Patient problems: Extravasation

    MAUDE report 23034149 ↗
  • MalfunctionOct 28, 2024Retraction Problem; Activation Failure; Retraction Problem; Activation Failure

    AS REPORTED THROUGH THE CLINICAL STUDY LVIS PAS: AE/EVENT TERM: DIFFICULTY GETTING THE PROXIMAL ASPECT OF THE DEVICE TO OPEN DUE TO SEVERE TORTUOSITY. INDEX PROCEDURE SUMMARY: DURING THE INDEX PROCEDURE ON (B)(6) 2018 TO TREAT LARGE, WIDE-NECKED OPHTHALMIC ICA ANEURYSM, LVIS 4X28 WAS DEPLOYED FROM THE ICA TERMINUS, ACROSS THE NECK OF THE ANEURYSM WHERE THE DEVICE WAS PACKED IN, AND ULTIMATELY INTO THE CAVERNOUS SEGMENT OF THE ICA. GIVEN SEVERE TORTUOSITY, SOME DIFFICULTY OCCURRED WITH GETTING THE PROXIMAL ASPECT OF THE DEVICE TO OPEN. IT WAS DECIDED TO COMPLETE THE COILING PORTION OF THE PROCEDURE TO ADDRESS THE PROXIMAL ASPECT OF THE DEVICE WITHOUT HAVING AN ADJACENT MICROCATHETER PRESENT. AFTER FULLY DEPLOYING AND DETACHING THE 9X30, COILING PROCEED WITH 5 ADDITIONAL AXIUM COILS AS FOLLOWS: 7X30 3D, 6X20 3D PRIME, 5X15 3D PRIME, 4X12 3D PRIME, 3X10 3D. THE ECHELON WAS THEN REMOVED. A SCEPTER XC 4X11 BALLOON WAS ADVANCED OVER A SYNCHRO WIRE IN AN ATTEMPT TO ANGIOPLASTY THE PROXIMAL ASPECT OF THE LVIS. GIVEN THE ACUITY OF THE ANGLES, COULD NOT SELECT THE INTERIOR OF THE DEVICE; HOWEVER, MANIPULATED THE BALLOON ALONGSIDE DEVICE. THIS PROVIDED ENOUGH FORWARD FORCE TO PUSH THE PROXIMA

    Patient problems: No Clinical Signs, Symptoms or Conditions; Thrombosis/Thrombus

    MAUDE report 20553177 ↗