Dissector MID1 (REF A000195)Recalls & reported problems
Atricure, Inc. · Articulating Dissection Instrument, 27 cm shaft · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00818354010367), received between Jun 30, 2024 and Jun 30, 2024 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Hemorrhage/Blood Loss/Bleeding1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 30, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A PATIENT UNDERWENT BILATERAL TT MAZE PROCEDURE USING A MID1 DISSECTOR. NEAR THE COMPLETION OF PROCEDURE, AN INJURY TO THE DOME OF THE LEFT ATRIUM OCCURRED. THE SURGEON DECIDED TO CONVERT ACCESS TO A STERNOTOMY TO REPAIR THE INJURY. THE INJURY WAS REPAIRED AND THE PROCEDURE WAS COMPLETED. THIS WAS A PROCEDURAL COMPLICATION, AND THERE WAS NO REPORTED DEVICE MALFUNCTION.
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 19641005 ↗
FDA clearance and classification
The FDA regulates product code GDI (dissector, surgical, general & plastic surgery) under 21 CFR 878.4800 as a Class I device. 21 CFR 878.4800 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Dissector MID1
Has the Dissector MID1 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00818354010367), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Dissector MID1?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Jun 30, 2024. That report lists patient problem “Hemorrhage/Blood Loss/Bleeding” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Dissector MID1?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Dissector MID1 FDA approved?
Devices of this type (product code GDI) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Atricure, Inc.
Who makes the Dissector MID1, and is it still sold?
The FDA's device database lists Atricure, Inc. as the company responsible for it (brand Dissector, model MID1). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Dissector, Surgical, General & Plastic Surgery devices
- FABCO 34911510First Aid Bandage CO Inc · Dissector, Surgical, General & Plastic Surgery1 recall0 reports
- Aveli AVE001Revelle Aesthetics, Inc. · Dissector, Surgical, General & Plastic Surgery29 reports
- T.L.I.F. 202718200Depuy Spine, LLC · DISSECTOR, SURGICAL, GENERAL & PLASTIC SURGERY22 reports
- DeRoyal 28-0801Deroyal Industries, Inc. · DISSECTOR, SURGICAL, GENERAL & PLASTIC SURGERY5 reports
- Dissector MID1Atricure, Inc. · Dissector, Surgical, General & Plastic Surgery1 report
- Dissector GPD1Atricure, Inc. · Dissector, Surgical, General & Plastic Surgery1 report
- Medicon 09.95.92Medicon eG. Chirurgiemechaniker-Genossenschaft · DISSECTOR, SURGICAL, GENERAL & PLASTIC SURGERY1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page