Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00819837020507), received between May 9, 2019 and May 9, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Detachment of Device or Device Component1
- Off-Label Use1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 9, 2019Break; Off-Label Use; Detachment of Device or Device Component
A SPINEEX DRIVER INSTRUMENT MALFUNCTIONED DURING SURGERY WHEN USED IMPROPERLY WITHOUT THE REQUIRED SPINEEX 2.25 N*M TORQUE LIMITING HANDLE. DURING STEP 7 OF THE SAGITTAE SURGICAL TECHNIQUE, DR. (B)(6) WAS USING THE SPINEEX SAGITTAE NAKED-DRIVER TO EXPAND THE ANTERIOR AND POSTERIOR SIDES OF THE SAGITTAE IMPLANT INDEPENDENTLY OF ONE ANOTHER. HE WAS USING THE SPINEEX 2.25 N*M TORQUE LIMITING HANDLE TO DO SO. WHEN HE WAS UNABLE TO GET ALL THE DESIRED TORQUE, HE WAS THEN LOOKING FOR OTHER METHODS TO EXPAND THE POSTERIOR SIDE OF THE IMPLANT, HE ASKED FOR A NON-TORQUE LIMITING T-HANDLE NOT PROVIDED BY SPINEEX TO CONNECT TO THE SPINEEX SAGITTAE NAKED-DRIVER IN HOPES OF OBTAINING MORE TORQUE. SPINEEX REPRESENTATIVES REMINDED DR. (B)(6) THAT THE SAGITTAE NAKED-DRIVER WAS NOT INTENDED TO BE USED WITHOUT THE SPINEEX PROVIDED 2.25 N*M TORQUE LIMITING HANDLE. DR. (B)(6) UNDERSTOOD THIS AND STILL REQUESTED FOR THE NON-SPINEEX PROVIDED NON-TORQUE LIMITING T-HANDLE. UPON CONNECTING THE NON-TORQUE LIMITING T-HANDLE TO THE SAGITTAE NAKED DRIVER, HE PROCEEDED TO APPLY A TORQUE IN THE WRONG DIRECTION (COUNTERCLOCKWISE) TO THE POSTERIOR SIDE OF THE IMPLANT. (B)(6) INSTRUCTED HIM HE WAS APPLYING THE TORQ
Patient problems: Foreign Body In Patient
MAUDE report 8596566 ↗
Other Intervertebral Fusion Device With Bone Graft, Lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page