- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00819917020434), received between Feb 22, 2025 and Feb 22, 2025 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 22, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
EVENT WAS IDENTIFIED AS PART OF A RETROSPECTIVE CLINICAL STUDY: 6-MONTHS POST-OPERATIVE SHOW SUBSIDENCE (NOT MEASURED; ONLY THE INTERSPINOUS DISTANCES IN THE FLEXION AND EXTENSION VIEWS) INTO THE SUPERIOR ENDPLATE OF C7 WITH THE GRAFT, WHICH HAS PROGRESSED TO A SOLID FUSION. THERE IS NEUTRAL ALIGNMENT FROM C2 TO T1. THERE IS STILL 3 MM OF MOTION ON FLEXION AND EXTENSION VIEWS, SUGGESTING THAT THE PATIENT IS NOT FULLY FUSED AT THIS POINT 6 MONTHS POSTOPERATIVE. HOWEVER, THE AP VIEW REVEALS BONE GRAFT LATERAL TO THE SPACER ON BOTH SIDES WHICH DOES GENERALLY APPEAR TO BE FUSED, SO CERTAINLY APPROACHING FUSION, BUT NOT QUITE THERE YET. 12.5-MONTHS POST-OPERATIVE SHOW A SOLID FUSION NOW AT C6-7 WITH SOME SUBSIDENCE (MEASUREMENT NOT CAPTURED) OF THE INTERBODY SPACER INTO THE C7 SUPERIOR ENDPLATE AND LESS THAN 1 MM OF MOTION ON FLEXION AND EXTENSION VIEWS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21440461 ↗
Other Intervertebral fusion device with bone graft, cervical devices
- EIT CIF cage CUI8070SEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall4 reports
- ROI-C MC1005TLDR Spine Usa, Inc. · Intervertebral Fusion Device With Bone Graft, Cervical54 reports
- EIT CIF cage CUI8060LEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall1 report
- CONSTRUX - MINI PTC 37-5012SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-6211SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-7308SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-9207SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-6106SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page