TurboHawkTM TH-LS-MRecalls & reported problems
Covidien LP · ATHERECTOMY TH-LS-M TURBOHAWK ATK V06 · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00821684065747), received between Sep 20, 2017 and Sep 20, 2017 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device Damaged by Another Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device Damaged by Another Device1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 20, 2017Device Damaged by Another Device; Device Damaged by Another Device
THE PHYSICIAN WAS ATTEMPTING TO USE A TURBOHAWK DIRECTIONAL ATHERECTOMY DEVICE TO TREAT A MODERATELY CALCIFIED LESION IN THE SFA. THE ARTERY WAS 5-6 MM IN DIAMETER. THE DEVICE WAS PREPPED AS PER THE IFU. A 7 FRENCH NON-MEDTRONIC SHEATH WAS USED AND WITH A "0.014 NON-MEDTRONIC GUIDEWIRE. IT WAS REPORTED THAT AFTER 4 SUCCESSFUL PASSES WITH THE TURBOHAWK DEVICE, THE PHYSICIAN NOTICED THE DEVICE WAS NOT SHOWING AS FULL BUT FELT AS IF IT WAS. THE DEVICE WAS INSPECTED, WHEN THE DEVICE WAS REMOVED SOMETHING THAT LOOKED LIKE A PIECE OF PLASTIC WAS FOUND IN THE CUTTER WINDOW. THE CUTTER COULD NOT BE RETURNED TO THE HOUSING. A PTA BALLOON AND STENT WERE USED TO COMPLETE THE PROCEDURE. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6881684 ↗
Other Catheter, peripheral, atherectomy devices
- HawkOne™ H1-MCovidien LP · Catheter, peripheral, atherectomy1 recall367 reports
- JETSTREAM™ XC 112266-001Boston Scientific Corporation · Catheter, peripheral, atherectomy288 reports
- JETSTREAM™ XC 112264-001Boston Scientific Corporation · Catheter, peripheral, atherectomy262 reports
- SET Rotarex®S 6F 135cm (Straub Medical®) Version 1.0Straub Medical AG · Catheter, Peripheral, Atherectomy2 deaths206 reports
- SET Rotarex™S 6 F x 135 cm 80237Straub Medical AG · Catheter, Peripheral, Atherectomy1 recall79 reports
- HawkOne™ H1-SCovidien LP · Catheter, peripheral, atherectomy1 recall70 reports
- Turbo-Elite Laser Atherectomy Catheter 420-006Spectranetics Corporation · Catheter, Peripheral, Atherectomy2 recalls19 reports
- Turbo-Elite Laser Atherectomy Catheter 417-152Spectranetics Corporation · Catheter, Peripheral, Atherectomy2 recalls16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page