Skip to content

Berkeley Vacurette 21593ARecalls & reported problems

Gyrus ACMI, LLC · VACURETTE CURVED 14 MM (10/PK) · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00821925038004), received between Nov 25, 2019 and Nov 25, 2019 — classified as 1 malfunction.

The most frequently reported specific device problem is “Device Markings/Labelling Problem” (1 report).

1 other recall cover devices cleared under the same FDA submission (K171440); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Device Markings/Labelling Problem1
  • Manufacturing, Packaging or Shipping Problem1

Patient problems

  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 25, 2019Device Markings/Labelling Problem; Manufacturing, Packaging or Shipping Problem

    SURGEON REQUESTED 10MM CURVED VACURETTE CANNULA. THE APPROPRIATE SIZE PER PACKAGING WAS SELECTED AND OPENED. UPON INSPECTION, IT SEEMED TOO LARGE. FURTHER INSPECTION OF THE PACKAGING REVEALED THAT THE WRONG SIZE INDICATOR HAD BEEN PLACED INSIDE THE PACKAGING BY THE MANUFACTURER. THE ACTUAL SIZE OF THE CANNULA WAS 14MM. A SIZE 10MM CANNULA WAS THEN OPENED AND USED FOR THE PROCEDURE. PER THE CIRCULATOR, THE PACKAGE INSERT STATING SIZE AND WHAT SHE READS TO CHOOSE REQUESTED SIZE SHOWS THE SIZE AS 10MM. THE OUTER PACKAGING STATES THE SIZE AS 14MM. SHE REPORTED THAT THE INK COLOR FOR THE INSERT IS RED FOR THE 10MM AND 14MM. SHE SUGGESTED TO HAVE A DIFFERENT COLOR FOR EACH SIZE CANNULA FOR BETTER VISUALIZATION AND EASE IN OBTAINING THE DESIRED SIZE. THE SIZE ON THE OUTER PACKAGING IS ALSO DIFFICULT TO FIND AND WRITING IS VERY SMALL. CURRENT INVENTORY WAS ASSESSED AND THIS ONE CANNULA BEING REPORTED WAS THE ONLY FOUND WITH INCORRECT PACKAGING. CURVED VACURETTE CANNULA AND PACKAGING (INNER AND OUTER) SAVED FOR QUALITY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9368754 ↗

FDA clearance and classification

Cleared through Special 510(k) K171440 on Sep 29, 2017 (decision: Substantially Equivalent). Submitted by Gyrus Acmi as “Berkeley VC-10 Vacuum Curettage System”. The FDA review took 136 days. FDA record ↗

The FDA regulates product code HHK (curette, suction, endometrial (and accessories)) under 21 CFR 884.1175 as a Class II device. 21 CFR 884.1175 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K171440. One submission often covers many models, so check the product and lot details in each record.

  • Z-0078-2023 · Sep 16, 2022 · Open, Classified
    Berkeley VC-10 Vacuum Curettage System, Model No. VC-10. For transcervical aspiration of the uterine cavity.

Common questions about the Berkeley Vacurette 21593A

Has the Berkeley Vacurette 21593A been recalled?

No FDA recall record in our data names this exact device identifier (DI 00821925038004), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.

What problems have been reported with the Berkeley Vacurette 21593A?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Nov 25, 2019. That report lists device problems “Device Markings/Labelling Problem” (1) and “Manufacturing, Packaging or Shipping Problem” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Berkeley Vacurette 21593A?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Berkeley Vacurette 21593A FDA approved?

It was cleared through Special 510(k) K171440 on Sep 29, 2017. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Berkeley Vacurette 21593A, and is it still sold?

The FDA's device database lists Gyrus ACMI, LLC as the company responsible for it (brand Berkeley Vacurette, model 21593A). Its record shows it as no longer in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Curette, Suction, Endometrial (And Accessories) devices

All Curette, Suction, Endometrial (And Accessories) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page