Drive 12011KD-1Recalls & reported problems
Drive Devilbiss Healthcare · Transfer Bench KD,Tool Free, 1/cs · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 1
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00822383224916), received between Feb 10, 2022 and Feb 21, 2024 — classified as 1 death, 5 injuries, 3 malfunctions.
The most frequently reported specific device problem is “Device Slipped” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Slipped2
- Fracture2
- Insufficient Device Problem Information2
- Material Integrity Problem2
- Material Fragmentation1
Patient problems
- Fall6
- Blister1
- Head Injury1
- Hemorrhage/Blood Loss/Bleeding1
- Insufficient Information1
- Limb Pain1
- Skin Infection1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
InjuryFeb 21, 2024Material Integrity Problem; Material Integrity Problem
DRIVE DEVILBISS HEALTHCARE WAS NOTIFIED OF AN INCIDENT INVOLVING A TRANSFER BENCH BY A PROVIDER, WHO REPORTED THAT THE SEAT STARTED TO COLLAPSE AND CAUSED PRESSURE ON THE END USER'S LEG, RESULTING IN A BLISTER THAT REQUIRED AN ANTIBIOTIC FOR TREATMENT. DRIVE DEVILBISS HEALTHCARE IS CURRENTLY INVESTIGATING THE INCIDENT. AN UPDATE WILL BE FILED IF ADDITIONAL INFORMATION BECOMES AVAILABLE.
Patient problems: Blister
MAUDE report 18748663 ↗InjuryJan 12, 2024Material Integrity Problem; Material Integrity Problem
DRIVE DEVILBISS HEALTHCARE WAS NOTIFIED OF AN INCIDENT INVOLVING A TRANSFER BENCH BY THE END USER'S SPOUSE, WHO REPORTED THAT THE FRONT LEG OF THE DEVICE COLLAPSED WHILE IN USE. THE END USER IS AN AMPUTEE THAT RECENTLY HAD SURGERY ON HIS STUMP. HE REPORTEDLY FELL ONTO HIS STUMP AND DEVELOPED A STAPHYLOCOCCUS/PSEUDOMONAS INFECTION THAT WAS TREATED WITH ANTIBIOTICS. DRIVE DEVILBISS HEALTHCARE IS CURRENTLY INVESTIGATING THE INCIDENT. AN UPDATE WILL BE FILED IF ADDITIONAL INFORMATION BECOMES AVAILABLE.
Patient problems: Skin Infection
MAUDE report 18504192 ↗MalfunctionJun 20, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
DRIVE DEVILBISS HEALTHCARE WAS NOTIFIED OF A COMPLAINT REGARDING A BATH BENCH BY AN END USER'S DAUGHTER, WHO STATED THAT HER FATHER "FELL OFF THE CHAIR AND HIT HIS HEAD." THERE WERE NO ADDITIONAL DETAILS AS TO THE NATURE OF THE INJURY OR PRODUCT MALFUNCTION. THERE WAS NO REPORT OR EVIDENCE OF MEDICAL TREATMENT ASSOCIATED WITH THE COMPLAINT. DRIVE IS CURRENTLY INVESTIGATING THE INCIDENT, INCLUDING ATTEMPTING TO RETRIEVE THE PRODUCT AND INSPECT IT, AND WILL FILE AN UPDATE IF ADDITIONAL INFORMATION BECOMES AVAILABLE.
Patient problems: Fall; Head Injury
MAUDE report 17167197 ↗MalfunctionJun 16, 2023Fracture; Fracture
DRIVE DEVILBISS HEALTHCARE WAS NOTIFIED OF AN INCIDENT INVOLVING A BATH BENCH BY AN END USER, WHO STATED THAT ONE OF THE LEGS OF THE UNIT "BROKE," AND SHE REPORTEDLY "FELL FORWARD." THERE WAS NO REPORT OR EVIDENCE OF ILLNESS, INJURY OR MEDICAL TREATMENT ASSOCIATED WITH THE COMPLAINT. DRIVE IS CURRENTLY INVESTIGATING THE INCIDENT, INCLUDING ATTEMPTING TO RETRIEVE THE PRODUCT AND INSPECT IT, AND WILL FILE AN UPDATE IF ADDITIONAL INFORMATION BECOMES AVAILABLE.
Patient problems: Fall
MAUDE report 17148210 ↗MalfunctionApr 7, 2023Device Slipped; Device Slipped
DRIVE DEVILBISS HEALTHCARE WAS NOTIFIED OF AN INCIDENT INVOLVING A CANE BY AN END USER, WHO STATED THAT "WHILE WALKING WITH THE CANE IT GOT WET AND HE SLIPPED AND FELL." THE END USER HIT HIS HEAD BUT DID NOT SEEK MEDICAL ATTENTION. DRIVE IS CURRENTLY INVESTIGATING THE INCIDENT, INCLUDING ATTEMPTING TO RETRIEVE THE PRODUCT AND INSPECT IT, AND WILL FILE AN UPDATE IF ADDITIONAL INFORMATION BECOMES AVAILABLE.
Patient problems: Fall
MAUDE report 16699645 ↗InjuryMar 6, 2023Fracture; Fracture
DRIVE DEVILBISS HEALTHCARE WAS NOTIFIED OF AN INCIDENT INVOLVING A TRANSFER BENCH BY AN END USER'S BROTHER, WHO STATED THAT "HIS BROTHER WAS USING THE TRANSFER BENCH AND THE LEG BROKE, CAUSING HIM TO FALL." HE WAS TRANSPORTED TO THE HOSPITAL FOR INJURED HIPS, KNEES AND A SORE ON HIS FOOT. HE IS CURRENTLY BACK AT HIS ASSISTED LIVING RESIDENCE AND IS RECEIVING THERAPY. DRIVE IS CURRENTLY INVESTIGATING THE INCIDENT, INCLUDING ATTEMPTING TO RETRIEVE THE PRODUCT AND INSPECT IT, AND WILL FILE AN UPDATE IF ADDITIONAL INFORMATION BECOMES AVAILABLE.
Patient problems: Fall; Limb Pain
MAUDE report 16486529 ↗InjuryMar 6, 2023Device Slipped; Device Slipped
DRIVE DEVILBISS HEALTHCARE WAS NOTIFIED OF AN INCIDENT INVOLVING A CANE BY AN END USER, WHO STATED THAT "WHILE WALKING WITH THE CANE IT GOT WET AND HE SLIPPED AND FELL." THE END USER HIT HIS HEAD BUT DID NOT SEEK MEDICAL ATTENTION. DRIVE IS CURRENTLY INVESTIGATING THE INCIDENT, INCLUDING ATTEMPTING TO RETRIEVE THE PRODUCT AND INSPECT IT, AND WILL FILE AN UPDATE IF ADDITIONAL INFORMATION BECOMES AVAILABLE.
Patient problems: Fall
MAUDE report 16485683 ↗DeathDec 16, 2022Insufficient Device Problem Information; Insufficient Device Problem Information
DRIVE DEVILBISS HEALTHCARE WAS NOTIFIED OF AN INCIDENT INVOLVING A TRANSFER BENCH BY AN END USER, WHO STATED THAT HE SUSTAINED "BLEEDING AND INJURY" WHILE TRANSFERRING OUT OF HIS TUB. DRIVE IS CURRENTLY INVESTIGATING THE INCIDENT, INCLUDING ATTEMPTING TO RETRIEVE THE PRODUCT AND INSPECT IT, AND WILL FILE AN UPDATE IF ADDITIONAL INFORMATION BECOMES AVAILABLE.
Patient problems: Hemorrhage/Blood Loss/Bleeding; Insufficient Information
MAUDE report 15995352 ↗InjuryFeb 10, 2022Material Fragmentation; Material Fragmentation
DRIVE DEVILBISS HEALTHCARE WAS NOTIFIED OF AN INCIDENT WITH A BATH BENCH ON (B)(6). THE END-USER STATED THAT THE LEG OF HER BATH BENCH BROKE WHILE IN USE CAUSING HER TO FALL AND HIT HER HEAD. SHE "CALLED THE AMBULANCE TO ASSIST HER OUT OF THE TUB AND THEN TAKE HER TO THE HOSPITAL AND THEY SAID A DOCTOR WILL COME TO HER HOME SINCE THE HOSPITAL WAS FULL." SHE HAS NOT RETURNED THE UNIT. DRIVE DEVILBISS HEALTHCARE IS CURRENTLY INVESTIGATING THE INCIDENT, INCLUDING ATTEMPTING TO RETRIEVE THE PRODUCT AND INSPECT IT, AND WILL FILE AN UPDATE AS SOON AS ADDITIONAL INFORMATION BECOMES AVAILABLE.
Patient problems: Fall
MAUDE report 13510613 ↗
Other ADAPTOR, HYGIENE devices
- DRIVEMEDICAL RTL12505Drive Devilbiss Healthcare · ADAPTOR, HYGIENE19 reports
- Drive RTL12202KDRDrive Devilbiss Healthcare · ADAPTOR, HYGIENE11 reports
- Drive RTL12203KDRDrive Devilbiss Healthcare · ADAPTOR, HYGIENE9 reports
- DRIVEMEDICAL 12486Drive Devilbiss Healthcare · ADAPTOR, HYGIENE6 reports
- DMI 522-1702-1900D-M-S Holdings, Inc. · Adaptor, Hygiene5 reports
- Drive 11135-1Drive Devilbiss Healthcare · ADAPTOR, HYGIENE4 reports
- Aquasence 770-525Drive Devilbiss Healthcare · ADAPTOR, HYGIENE4 reports
- DRIVEMEDICAL 12202KD-4Drive Devilbiss Healthcare · ADAPTOR, HYGIENE4 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page