DRIVEMEDICAL GV974GY-TRecalls & reported problems
Drive Devilbiss Healthcare · Rollators4-Wheel Alum Product Description: F22 Rollator, Tall, Grey · Class 1
All models of DRIVEMEDICAL (111)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00822383964157), received between Jul 30, 2025 and Jul 30, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Damaged Thread” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Damaged Thread1
Patient problems
- Bone Fracture(s)1
- Joint Dislocation1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 30, 2025Damaged Thread; Damaged Thread
DRIVE DEVILBISS HEALTHCARE WAS NOTIFIED OF AN INCIDENT INVOLVING A ROLLATOR BY THE END USER'S DAUGHTER, WHO REPORTED THAT A WHEEL CAME OFF DURING USE CAUSING THE END USER TO FALL AND SUSTAIN A BROKEN AND DISLOCATED SHOULDER. DRIVE DEVILBISS EVALUATED THE ROLLATOR AND CONFIRMED THE DETACHED WHEEL. UPON FURTHER INSPECTION IT WAS DISCOVERED THAT THE HOUSING FOR THE SCREW ON THE FRONT FORK WAS STRIPPED, MOST LIKELY DUE TO OVERTIGHTENING OF THE SCREW DURING MAINTENANCE, THEREFORE CREATING A WEAK BOND BETWEEN THE SCREW AND THE FRONT FORK. AS PART OF ITS COMPLAINT REVIEW AND EVALUATION PROCESS, DRIVE DEVILBISS HEALTHCARE WILL ALSO NOTIFY THE MANUFACTURER OF THE PRODUCT ABOUT THIS COMPLAINT.
Patient problems: Bone Fracture(s); Joint Dislocation
MAUDE report 22665403 ↗
Other WALKER, MECHANICAL devices
- Drive 10257BL-1Drive Devilbiss Healthcare · WALKER, MECHANICAL13 reports
- Drive R726RDDrive Devilbiss Healthcare · WALKER, MECHANICAL1 death10 reports
- Drive 790Drive Devilbiss Healthcare · WALKER, MECHANICAL10 reports
- Drive R728BLDrive Devilbiss Healthcare · WALKER, MECHANICAL9 reports
- Drive 10257RD-1Drive Devilbiss Healthcare · WALKER, MECHANICAL9 reports
- DRIVEMEDICAL 795BDrive Devilbiss Healthcare · WALKER, MECHANICAL9 reports
- Drive R726BKDrive Devilbiss Healthcare · WALKER, MECHANICAL9 reports
- Drive 10215BL-1Drive Devilbiss Healthcare · WALKER, MECHANICAL8 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page