Skip to content

Ovation Hip Stem 101-0005Recalls & reported problems

Ortho Development Corporation · STD Size 5 Stem Plasma Spray · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00822409010844), received between Apr 18, 2023 and Oct 18, 2023 — classified as 2 injuries.

4 other recalls cover devices cleared under the same FDA submission (K062775); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2

Patient problems

  • Arthralgia2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 18, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DURING HIP ARTHROPLASTY, AN INTRAOPERATIVE FRACTURE WAS OBSERVED IN THE INFERIOR END OF THE LESSER TROCHANTER THAT WAS REINFORCED WITH CABLING.

    Patient problems: Arthralgia

    MAUDE report 17961168 ↗
  • InjuryApr 18, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    WHILE BROACHING DURING TOTAL HIP ARTHROPLASTY, A LONGITUDINAL BONE FRACTURE OCCURRED THAT THE SURGEON REINFORCED WITH CABLE AND COMPLETED THE OPERATION WITHOUT PROBLEMS.

    Patient problems: Arthralgia

    MAUDE report 16765567 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K062775. One submission often covers many models, so check the product and lot details in each record.

  • Z-1670-2011 · Jan 11, 2011 · Terminated
    Ovation Hip Stem, REF 201-0002, Hip Stem Inserter, Non-Sterile, Ortho Development, Draper, Utah 84020. The Ovation Hip System is intended for use in total hip arthroplasty. The hip
  • Z-1673-2011 · Jan 11, 2011 · Terminated
    Ovation Hip Stem, REF 201-0104, Offset Stem Inserter Neutral, Non-Sterile, Ortho Development, Draper, Utah 84020. The Ovation Hip System is intended for use in total hip arthroplas
  • Z-1672-2011 · Jan 11, 2011 · Terminated
    Ovation Hip Stem, REF 201-0103, Offset Stem Inserter LT, Non-Sterile, Ortho Development, Draper, Utah 84020. The Ovation Hip System is intended for use in total hip arthroplasty. T
  • Z-1671-2011 · Jan 11, 2011 · Terminated
    Ovation Hip Stem, REF 201-0102, Offset Stem Inserter RT, Non-Sterile, Ortho Development, Draper, Utah 84020. The Ovation Hip System is intended for use in total hip arthroplasty. T

Other Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices

All Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page