Hawkins-Akins G05042Recalls & reported problems
Cook Incorporated · Disp Hawkins-Akins Blunt Needle · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002050426), received between Jun 8, 2018 and Jun 8, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 8, 2018Break; Break
IT WAS REPORTED A HAWKINS-AKINS BLUNT NEEDLE TIP BROKE DURING PERITONEAL DIALYSIS (PD) DRAINAGE. THE DEVICE WAS PLACED IN AN UPPER EXTREMITY WHEN THE DISTAL TIP OF THE WIRE BECAME LODGED IN THE NEEDLE. THE PATIENT'S ANATOMY WAS NOT NOTED TO BE SIGNIFICANTLY TORTUOUS OR CALCIFIED, NOR ANY DAMAGE NOTED TO THE WIRE PRIOR-TO-USE. THE DOCTOR APPLIED MORE PRESSURE IN AN ATTEMPT TO DISASSOCIATE THE TWO DEVICES, HOWEVER, THIS CAUSED THE TIP TO BECOME DETACHED IN THE CANNULA OF THE NEEDLE. THE DETACHED FRAGMENT/TIP WAS REMOVED ALONG WITH THE NEEDLE AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY USING AN ALTERNATIVE DEVICE. AS REPORTED, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS OR REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7583293 ↗
Other ACCESSORIES, CATHETER devices
- Cook G00219Cook Incorporated · ACCESSORIES, CATHETER103 reports
- Discofix® 456020B. Braun Medical Inc. · ACCESSORIES, CATHETER60 reports
- IV Administration Set 490062B. Braun Medical Inc. · ACCESSORIES, CATHETER1 recall0 reports
- Centeze Centesis Catheter DRC-002-06Galt Medical Corp. · Accessories, Catheter1 recall0 reports
- Extension Set 456025B. Braun Medical Inc. · ACCESSORIES, CATHETER1 recall0 reports
- Centeze Centesis Catheter DRC-002-05Galt Medical Corp. · Accessories, Catheter1 recall0 reports
- Neff G10544Cook Incorporated · ACCESSORIES, CATHETER45 reports
- Cook G06299Cook Incorporated · ACCESSORIES, CATHETER18 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page