Cook G14873Recalls & reported problems
Cook Incorporated · Spiral Tip Ureteral Access Catheter · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00827002148734), received between May 11, 2017 and May 12, 2017 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Device Damaged Prior to Use1
- Material Separation1
Patient problems
- Device Embedded In Tissue or Plaque1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 12, 2017Device Damaged Prior to Use; Device Damaged Prior to Use
THE CUSTOMER REPORTED THAT THE TIP OF SPIRAL TIP URETERAL ACCESS CATHETER WAS FOUND BROKEN PRIOR TO USE. THE DEVICE DID NOT COME IN CONTACT WITH THE PATIENT. THERE WAS NO PATIENT HARM REPORTED AND NO ADDITIONAL PROCEDURES WERE REQUIRED BECAUSE OF THIS FAILURE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6563101 ↗InjuryMay 11, 2017Break; Material Separation; Break; Material Separation
IT WAS REPORTED THAT THE PHYSICIAN WAS PERFORMING URETEROSCOPY PROCEDURE ON A PATIENT BY USING SPIRAL TIP URETERAL ACCESS CATHETER. DURING THE PROCEDURE, THE TIP OF THE DEVICE BROKE OFF INSIDE THE PATIENT. THE PHYSICIAN DRAINED THE PATIENT'S BLADDER TO REMOVE THE BROKEN PIECE OF THE TIP. NO UNINTENDED SECTION OF THE DEVICE REMAINED INSIDE THE PATIENT¿S BODY. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE. NO ADDITIONAL INFORMATION HAS BEEN PROVIDED AT THIS TIME.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 6559967 ↗
Other CATHETER, UROLOGICAL devices
- Magic3™ Coude Intermittent Catheter with Sure-Grip™ Sleeve 50614C. R. Bard, Inc. · CATHETER, UROLOGICAL883 reports
- Magic3™ Intermittent Catheter with Sure-Grip™ Sleeve 53614GC. R. Bard, Inc. · CATHETER, UROLOGICAL692 reports
- Magic3™ Coude Intermittent Catheter with Sure-Grip™ Sleeve 50616C. R. Bard, Inc. · CATHETER, UROLOGICAL2 deaths443 reports
- GENTLECATH GLIDE 421567Convatec, Purchasing Department · Catheter, Urological342 reports
- Magic3™ Intermittent Catheter with Sure-Grip™ Sleeve 53616GC. R. Bard, Inc. · CATHETER, UROLOGICAL301 reports
- Bardex® Foley Catheter Silicone Coated 0167V22SC. R. Bard, Inc. · CATHETER, UROLOGICAL187 reports
- Bardex® Foley Catheter Silicone Coated 0167V20SC. R. Bard, Inc. · CATHETER, UROLOGICAL175 reports
- Bardia® Coude Olive Tip Urethral Foley Catheter 802516C. R. Bard, Inc. · CATHETER, UROLOGICAL170 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page