LapSac G16495Recalls & reported problems
Cook Incorporated · LapSac Surgical Tissue Pouch · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002164956), received between Aug 9, 2023 and Aug 9, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device Contaminated During Manufacture or Shipping” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device Contaminated During Manufacture or Shipping1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 9, 2023Device Contaminated During Manufacture or Shipping; Device Contaminated During Manufacture or Shipping
ADDITIONAL INFORMATION RECEIVED ON 09AUG2023: THE PACKAGING MATERIAL WAS INTACT. THE PACKAGE WAS SAID TO BE STORED IN COMPLIANCE WITH STANDARD SPECIFICATIONS. THE STAINS WERE NOTED UPON INSPECTION PRIOR TO USE AND THE DEVICE WAS NOT USED FOR THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17492102 ↗
Other BAG, INTESTINE devices
- LapSac G16496Cook Incorporated · BAG, INTESTINE3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page