CXI G23864Recalls & reported problems
Cook Incorporated · CXI Support Catheter · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002238640), received between Oct 24, 2025 and Oct 24, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 24, 2025Break; Break
ADDITIONAL INFORMATION WAS RECEIVED 24OCT2025. THE PROCEDURE INVOLVED MULTIPLE INTERVENTIONS INCLUDING INTRAVASCULAR LITHOTRIPSY, PERCUTANEOUS TRANSLUMINAL BALLOON ANGIOPLASTY, AND STENT PLACEMENT. THE PATIENT HAD MULTI-LEVEL AORTOILIAC OCCLUSIVE DISEASE OF THE RIGHT LOWER EXTREMITY, AND THE RIGHT SUPERFICIAL FEMORAL AND POSTERIOR TIBIAL ARTERIES WERE OCCLUDED. ACCESS WAS OBTAINED IN THE LEFT FEMORAL ARTERY TO TARGET THE RIGHT LOWER EXTREMITY, DOWN TO THE POSTERIOR TIBIAL ARTERY. THE CATHETER WAS ADVANCED THROUGH ANOTHER MANUFACTURER¿S 45-CENTIMETER SHEATH, AND MULTIPLE WIRES WERE USED DURING THE PROCEDURE. IT IS UNKNOWN IF RESISTANCE WAS ENCOUNTERED UPON INSERTION OR ADVANCEMENT OF THE CATHETER. A POWER INJECTOR WAS NOT USED. THE DEVICE SEPARATED IN THE MIDDLE OF THE PROCEDURE. IT IS UNKNOWN WHAT WAS ATTACHED TO THE HUB AT THE TIME OF THE EVENT. THE CATHETER WAS MANUALLY REMOVED FROM THE PATIENT. THE PROCEDURE WAS COMPLETED SUCCESSFULLY, WITH IN-LINE FLOW VIA PERONEAL ARTERY RUNOFF WITH MULTI-PHASIC PEDAL DOPPLER SIGNALS AFTER THE INTERVENTIONAL PROCEDURE. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES OR EXP
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23378661 ↗
Other Catheter, continuous flush devices
- PROWLER SELECT 606-S255XMedos International Sàrl · Catheter, continuous flush2 deaths980 reports
- PhenomTM 27 Catheter FG15150-0615-1SMicro Therapeutics, Inc. · Catheter, continuous flush2 deaths139 reports
- MarathonTM 105-5056Micro Therapeutics, Inc. · Catheter, continuous flush124 reports
- Renegade™ HI-FLO™ Kit M001183020Boston Scientific Corporation · Catheter, continuous flush109 reports
- MarksmanTM FA-55150-1030Micro Therapeutics, Inc. · Catheter, continuous flush109 reports
- EkoSonic® 6779-002Boston Scientific Corporation · Catheter, Continuous Flush1 recall4 deaths56 reports
- Chameleon CH08-40-75USMozarc Medical US LLC · Catheter, continuous flush2 recalls4 reports
- RebarTM 105-5081-153Micro Therapeutics, Inc. · Catheter, continuous flush2 deaths102 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.