Byrd G26514Recalls & reported problems

Cook Vandergrift Inc. · 13.0 Fr Byrd Dilator Sheath Set (D) Polypropylene · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002265141), received between Sep 8, 2025 and Sep 8, 2025 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Cardiac Perforation1
  • Perforation of Vessels1
  • Pericardial Effusion1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjurySep 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A MAN IN HIS 70S, LEAD REMOVAL INDICATED DUE TO INFECTION AFTER PLACED FOR 25 YEARS. PLACED FROM THE RIGHT CHEST. PACEMAKER LEADS WERE EMBEDDED IN BOTH THE ATRIUM AND VENTRICLE. THE LOCKING STYLET USED WAS LR-OFA01 FOR BOTH. THE ATRIAL LEAD CAN BE REMOVED USING A 12FR LASER AND A 14FR LASER. THE VENTRICULAR LEAD HAD STRONG ADHESION AT THE TIP OF THE LEAD, AND ALTHOUGH THE SHEATH COULD REACH THE TIP OF THE LEAD USING EVOLUTION 11FR AND EVOLUTION 13FR, IT COULD NOT BE REMOVED FROM THE APEX OF THE HEART. THE PROCEDURE TOOK A LONG TIME AND THE LEAD STRETCHED, AND IT BROKE WHILE USING EVOLUTION 13FR. (THE STATE OF OFA COULD NOT BE CONFIRMED) THE LEAD HAD STRETCHED AND THINNED, AND WAS OUTSIDE THE BODY, SO A LONG THREAD (SIZE 2-0 OF SILK THREAD) WAS TIED TO IT AND USED AS A ROUTE TO PASS THE SHEATH FOR FREEING THE LEAD FROM THE ADHESIVE TISSUE. A 6FR MULTIPURPOSE CATHETER WAS PASSED THROUGH THE THREAD, AND A PPLBES7.0XL OUTER SHEATH WAS PLACED OVER IT, AND A PPLBES13 INNER SHEATH AND OUTER SHEATH WERE PLACED OVER THAT, AND THE PHYSICIAN ATTEMPTED TO FREE THE LEAD FROM THE ADHESIVE TISSUE. THE OPERATOR COMMENTED THAT "THE TIP OF THE SHEATH POKED THE VENTRICLE," AND LATER NOTED THE ACCUMUL

    Patient problems: Cardiac Perforation; Perforation of Vessels; Pericardial Effusion

    MAUDE report 22993264 ↗

FDA clearance and classification

The FDA regulates product code GCC (dilator, catheter) under 21 CFR 878.4200 as a Class I device. 21 CFR 878.4200 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Byrd G26514

Has the Byrd G26514 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00827002265141), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Byrd G26514?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 8, 2025. That report lists patient problems “Cardiac Perforation” (1), “Perforation of Vessels” (1) and “Pericardial Effusion” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Byrd G26514?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Byrd G26514 FDA approved?

Devices of this type (product code GCC) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Cook Vandergrift Inc.

Who makes the Byrd G26514, and is it still sold?

The FDA's device database lists Cook Vandergrift Inc. as the company responsible for it (brand Byrd, model G26514). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Dilator, catheter devices

All Dilator, catheter devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page