Byrd G26514Recalls & reported problems

Cook Vandergrift Inc. · 13.0 Fr Byrd Dilator Sheath Set (D) Polypropylene · Class 1

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002265141), received between Sep 8, 2025 and Sep 8, 2025 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Cardiac Perforation1
  • Perforation of Vessels1
  • Pericardial Effusion1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjurySep 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A MAN IN HIS 70S, LEAD REMOVAL INDICATED DUE TO INFECTION AFTER PLACED FOR 25 YEARS. PLACED FROM THE RIGHT CHEST. PACEMAKER LEADS WERE EMBEDDED IN BOTH THE ATRIUM AND VENTRICLE. THE LOCKING STYLET USED WAS LR-OFA01 FOR BOTH. THE ATRIAL LEAD CAN BE REMOVED USING A 12FR LASER AND A 14FR LASER. THE VENTRICULAR LEAD HAD STRONG ADHESION AT THE TIP OF THE LEAD, AND ALTHOUGH THE SHEATH COULD REACH THE TIP OF THE LEAD USING EVOLUTION 11FR AND EVOLUTION 13FR, IT COULD NOT BE REMOVED FROM THE APEX OF THE HEART. THE PROCEDURE TOOK A LONG TIME AND THE LEAD STRETCHED, AND IT BROKE WHILE USING EVOLUTION 13FR. (THE STATE OF OFA COULD NOT BE CONFIRMED) THE LEAD HAD STRETCHED AND THINNED, AND WAS OUTSIDE THE BODY, SO A LONG THREAD (SIZE 2-0 OF SILK THREAD) WAS TIED TO IT AND USED AS A ROUTE TO PASS THE SHEATH FOR FREEING THE LEAD FROM THE ADHESIVE TISSUE. A 6FR MULTIPURPOSE CATHETER WAS PASSED THROUGH THE THREAD, AND A PPLBES7.0XL OUTER SHEATH WAS PLACED OVER IT, AND A PPLBES13 INNER SHEATH AND OUTER SHEATH WERE PLACED OVER THAT, AND THE PHYSICIAN ATTEMPTED TO FREE THE LEAD FROM THE ADHESIVE TISSUE. THE OPERATOR COMMENTED THAT "THE TIP OF THE SHEATH POKED THE VENTRICLE," AND LATER NOTED THE ACCUMUL

    Patient problems: Cardiac Perforation; Perforation of Vessels; Pericardial Effusion

    MAUDE report 22993264 ↗

Other Dilator, catheter devices