Advance G44144Recalls & reported problems
Cook Incorporated · ATB Advance, PTA Dilatation Catheter · Class 2
All models of Advance (206)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002441446), received between Sep 14, 2018 and Sep 14, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Rupture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Rupture1
- Material Separation1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 14, 2018Material Rupture; Material Separation; Material Rupture; Material Separation
IT WAS REPORTED, WHILE INFLATING THE 12X4 ATB ADVANCE BALLOON CATHETER, IT RUPTURED CIRCUMFERENTIALLY AT 14 ATMOSPHERES DURING PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY OF THE BRACHIAL BASILIC ARTERIOVENOUS FISTULA. THIS WAS A VERY RESISTANT LESION. THE PHYSICIAN HAD USED A CUTTING BALLOON PRIOR TO USING THE COMPLAINT DEVICE TO HELP WITH DILITATION. PART OF THE BALLOON SEPARATED BEING LEFT IN THE PATIENT. THE PART LEFT IN THE PATIENT WAS THEN STUCK ON THE HYDRO ST WIRE. PHYSICIAN WAS THEN ABLE TO REMOVE THE WIRE WITH THE BROKEN PART OF BALLOON STUCK ON THE WIRE. THE SHEATH HAD TO BE REMOVED AS WELL. HEMOSTASIS WAS ACHIEVED USING MANUAL PRESSURE. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES AS A RESULT OF THIS OCCURRENCE. ACCORDING TO THE COMPLAINANT, ISOVUE 300 CONTRAST WAS USED IN A 70/30 MIXTURE WITH SALINE DURING THE PROCEDURE. THERE WAS NO VESSEL ANGULATION OR CALCIFICATION.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7878673 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.