CXI G56550Recalls & reported problems
Cook Incorporated · CXI Support Catheter · Class 2
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00827002565500), received between Feb 8, 2018 and May 22, 2025 — classified as 2 injuries, 4 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Material Separation2
- Contamination /Decontamination Problem1
- Material Deformation1
- Unsealed Device Packaging1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- Foreign Body In Patient2
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 22, 2025Unsealed Device Packaging; Unsealed Device Packaging
AS REPORTED, PRIOR TO A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA), THE CXI SUPPORT CATHETER'S PACKAGE WAS DISCOVERED TO BE UNSEALED WHEN THE USER ATTEMPTED TO OPEN IT. THE USER UTILIZED A NEW SAME TYPE OF DEVICE TO COMPLETE THE PROCEDURE. THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS OR REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22068944 ↗MalfunctionMar 12, 2024Contamination /Decontamination Problem; Material Deformation; Contamination /Decontamination Problem; Material Deformation
AS REPORTED, PRIOR TO USE FOR AN UNKNOWN PROCEDURE, A THIN STRAND OF PLASTIC CAME OFF THE SIDE OF A CXI SUPPORT CATHETER. THE CATHETER WAS REMOVED FROM THE PACKAGE, WHICH WAS NOT DAMAGED, AND WAS THEN FLUSHED AS NORMAL, WITHOUT DIFFICULTY. PRIOR TO ADVANCEMENT OF THE CATHETER OVER AN UNSPECIFIED WIRE GUIDE, THE CATHETER WAS INSPECTED, AND A THIN STRAND OF PLASTIC WAS NOTED TO COME FROM THE SIDE OF THE CATHETER, "ABOUT ONE-THIRD OF THE TOTAL LENGTH BACK FROM THE TIP". THE CATHETER WAS NEVER ADVANCED OVER THE WIRE. THE CATHETER WAS NOT USED AND NEVER ENTERED THE PATIENT. ANOTHER CATHETER WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO HARM TO THE PATIENT. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18886520 ↗InjuryJun 27, 2023Break; Break
NO ADDITIONAL INFORMATION REGARDING THE PATIENT AND/OR EVENT HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.
Patient problems: Foreign Body In Patient
MAUDE report 17209842 ↗MalfunctionMar 22, 2023Break; Break
NO ADDITIONAL INFORMATION REGARDING THE PATIENT AND/OR EVENT HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16589625 ↗InjuryMar 4, 2021Material Separation; Material Separation
NO ADDITIONAL INFORMATION REGARDING THE PATIENT AND/OR EVENT HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.
Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions
MAUDE report 11411070 ↗MalfunctionFeb 8, 2018Material Separation; Material Separation
IT WAS REPORTED THAT DURING AN UNSPECIFIED PROCEDURE, THE CXI SUPPORT CATHETER HUB SEPARATED FROM THE CATHETER UPON INITIAL USE OF THE DEVICE AFTER PASSING THE WIRE GUIDE. THE PHYSICIAN REMOVED THE DEVICE AND ANOTHER CATHETER WAS USED TO SUCCESSFULLY COMPLETE THE PROCEDURE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7252931 ↗
Other Catheter, continuous flush devices
- PROWLER SELECT 606-S255XMedos International Sàrl · Catheter, continuous flush2 deaths980 reports
- PhenomTM 27 Catheter FG15150-0615-1SMicro Therapeutics, Inc. · Catheter, continuous flush2 deaths139 reports
- MarathonTM 105-5056Micro Therapeutics, Inc. · Catheter, continuous flush124 reports
- Renegade™ HI-FLO™ Kit M001183020Boston Scientific Corporation · Catheter, continuous flush109 reports
- MarksmanTM FA-55150-1030Micro Therapeutics, Inc. · Catheter, continuous flush109 reports
- EkoSonic® 6779-002Boston Scientific Corporation · Catheter, Continuous Flush1 recall4 deaths56 reports
- Chameleon CH08-40-75USMozarc Medical US LLC · Catheter, continuous flush2 recalls4 reports
- RebarTM 105-5081-153Micro Therapeutics, Inc. · Catheter, continuous flush2 deaths102 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.