Pipeline PED-475-16 (UDI 00836462015586)Recalls & reported problems
Micro Therapeutics, Inc. · Flex Embolization Device · Class 3 · Implant
All models of PIPELINE (114)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00836462015586), received between Jun 24, 2020 and Dec 8, 2020 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Activation Failure” (1 report).
12 other recalls cover devices cleared under the same FDA submission (P100018); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Activation Failure1
- Detachment of Device or Device Component1
- Physical Resistance/Sticking1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 8, 2020Activation Failure; Physical Resistance/Sticking; Activation Failure; Physical Resistance/Sticking
MEDTRONIC RECEIVED A REPORT THAT THREE PIPELINES FAILED TO OPEN DISTALLY AND EXPERIENCED RESISTANCE IN THE DISTAL SEGMENT OF THE PHENOM 27 MICROCATHETER. THE PATIENT WAS UNDERGOING TREATMENT FOR AN UNRUPTURED, WIDE-NECKED, SACCULAR ANEURYSM LOCATED IN THE RIGHT INTERNAL CAROTID ARTERY. THE MAX DIAMETER WAS 7 MM, AND THE NECK DIAMETER WAS 4 MM. THE LANDING ZONE WAS 4.53 MM DISTAL AND 4.78 MM PROXIMAL. THE PATIENT¿S VESSEL TORTUOSITY WAS SEVERE AND WAS SAID TO HAVE A HIGH RIDING POSTERIOR GENU. THE ACCESS VESSEL WAS THE ICA AND WAS 4.78 MM IN DIAMETER. IT WAS REPORTED THAT THE PHENOM 27 MICROCATHETER WAS ADVANCE INTO THE M1 WITH A DEGREE OF DIFFICULTY. THE FIRST PIPELINE (4.5 X 20) WAS ATTEMPTED TO BE ADVANCE PAST THE ANEURYSM. THE PHYSICIAN EXPERIENCED A GREAT DEGREE OF RESISTANCE AND EVENTUALLY NAVIGATED INTO POSITION AND BEGAN TO UNSHEATHE THE DEVICE. APPROXIMATELY 50% OF THE DEVICE WAS UNSHEATHED AND THE DISTAL TINES OF THE PIPELINE WOULD NOT OPEN AND APPEARED TO BE FRAYED. THE DEVICE WAS REMOVED,AND A SECOND ATTEMPT WAS MADE WITH A 4.75 X 18 PIPELINE. THE PHYSICIAN ENCOUNTERED RESISTANCE AND ONCE IN POSITION AGAIN ATTEMPTED TO DEPLOY THE DEVICE. THE PIPELINE AGAIN OPENED IN THE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10972793 ↗MalfunctionJun 24, 2020Detachment of Device or Device Component; Detachment of Device or Device Component
MEDTRONIC RECEIVED INFORMATION THAT PIPELINE FLEX DELIVERY SYSTEM BROKE OFF AT RE-SHEATHING PAD. IT WAS REPORTED THAT AFTER PIPELINE FLEX WAS DEPLOYED, THE PHYSICIAN ATTEMPTED TO RECAPTURE DELIVERY SYSTEM IN STRAIGHT M1 SEGMENT, MET SIGNIFICANT RESISTANCE, STOPPED AND PULLED IT AND MICROCATHETER OUT. UPON INSPECTION ON BACK TABLE, DELIVERY SYSTEM BROKE OFF AT RE-SHEATHING PAD. THE DEVICE OPEN AND PLACED WHERE PHYSICIAN INTENDED. THERE WERE NOT ANY PATIENT SYMPTOMS OR COMPLICATIONS ASSOCIATED WITH THIS EVENT. DAPT (DUAL ANTIPLATELET TREATMENT) WAS ADMINISTERED. THE PRU LEVEL WAS IN NORMAL RANGE. NO IMAGES AVAILABLE FOR REVIEW. THE PATIENT WAS UNDERGOING EMBOLIZATION TREATMENT FOR A SMALL UNRUPTURED SACCULAR PARA OPHTHALMIC ANEURYSM, MEASURING 10MMX6MM, LANDING ZONE DISTAL 4.0MM, PROXIMAL 4.8MM. THE VESSEL OBSERVED NORMAL TORTUOUS. NO PATIENT INJURY WAS REPORTED. THE PIPELINE AND ANY ACCESSORY DEVICES WERE PREPARED AS INDICATED IN THE IFU.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10190735 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P100018. One submission often covers many models, so check the product and lot details in each record.
- Z-1245-2025 · Jan 30, 2025 · Open, ClassifiedMedtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-027-350-12, PED3-027-350-14, PED3-027-350-16, PED3-027-350-20, PED3-027-350-25, PED3-027-400-12, PE
- Z-1246-2025 · Jan 30, 2025 · Open, ClassifiedMedtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-021-350-16, PED3-021-250-14, PED3-021-350-20, PED3-021-250-20, PED3-021-300-16, PED3-021-300-20, PE
- Z-2403-2021 · Jul 13, 2021 · Open, ClassifiedEV3 Pipeline Flex Embolization Device with Flex Shield Technology
- Z-2402-2021 · Jul 13, 2021 · Open, ClassifiedPipeline Flex Embolization Device
- Z-1527-2020 · Feb 14, 2020 · Terminatedev3 Pipeline Flex Embolization Device. For neurological endovascular use.
- Z-0310-2017 · Oct 5, 2016 · TerminatedX-Celerator Hydrophilic Exchange Guidewire Catalog No. 103-0601-300 103-0601-350V10 103-0602-350V06 103-0601-300V01 103-0602-300 103-0602-350V09 103-0601-300V02 103-0602-300V01 10
- Z-0308-2017 · Oct 5, 2016 · TerminatedAlligator Retrieval Device The device is intended for use in the peripheral and neurovasculature for foreign body removal. Catalog No. FA-88810-20V04 FA-88810-20V06 FA-88810-30V04
- Z-0307-2017 · Oct 5, 2016 · TerminatedPipeline Embolization Device (Pipeline Classic) The device is indicated for the endovascular treatment of adults (22 year of age or older) with large or giant widenecked intracrani
- Z-0309-2017 · Oct 5, 2016 · TerminatedMarathon Flow Directed Micro Catheter, UltraFlow HPC Flow Directed Micro Catheter Marathon Flow: The device is intended to access periphera and neurovasculature for the controlled
- Z-0120-2016 · Sep 4, 2015 · Terminated-Pipeline Embolization Device -Pipeline Flex Embolization Device The Pipeline and Pipeline Flex Embolization Devices consist of a permanent implant combined with a guidewire based
- Z-1453-2014 · Apr 1, 2014 · TerminatedPipeline Embolization Device (PED). Used endovascular treatment of adults with intracranial aneurysms in the internal carotid artery.
- Z-2045-2013 · Jul 19, 2013 · TerminatedPipeline Embolization Device (PED) The Pipeline Embolization Device is indicated for the endovascular treatment of adults (22 years of age and older) with large or giant wide-neck
Other Intracranial aneurysm flow diverter devices
- Pipeline TM Flex Embolization Device with Shield Technology TM PED2-300-12Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter2 recalls1 report
- PIPELINE PED-500-20Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall31 reports
- PIPELINE PED-500-35Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall1 death29 reports
- PIPELINE PED-500-16Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall2 deaths27 reports
- PIPELINE PED-500-25Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall1 death23 reports
- PIPELINE PED-500-30Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall21 reports
- PIPELINE PED-450-25Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall20 reports
- PIPELINE PED-475-30Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall1 death19 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page