iLINK-BIS-10Recalls & reported problems
Oscor Inc. · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00836559004745), received between Mar 26, 2020 and Mar 26, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “High impedance” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- High impedance1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 26, 2020High impedance; High impedance
IT WAS REPORTED THAT ADAPTOR SHOWS HIGH IMPEDANCE WHEN TRIED TO CONNECT CRT-D PLATINIUM 1811. ADAPTOR WAS DISCONNECTED AND CONNECTED AGAIN TO BOTH LEADS BUT STILL HIGH IMPEDANCE WAS NOTICED. PATIENT OUTCOME IS STABLE. THE ADAPTOR WAS POSITIONED AT THE POCKET TOGETHER WITH OTHER ELECTRODES AND DEVICE. THE ADAPTOR WAS USED TO CONNECT THE TWO LEFT VENTRICLE ELECTRODES TO THE CRM SYSTEM. ADAPTOR WAS REPLACED WITH ANOTHER OSCOR BRANDED ADAPTOR WHICH IS WORKING PROPERLY WITH GOOD VALUES. NO OTHER INFORMATION IS AVAILABLE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9887113 ↗
FDA clearance and classification
The FDA regulates product code DTD (pacemaker lead adaptor) under 21 CFR 870.3620 as a Class II device. 21 CFR 870.3620 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the iLINK-BIS-10
Has the iLINK-BIS-10 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00836559004745), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the iLINK-BIS-10?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 26, 2020. That report lists device problem “High impedance” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the iLINK-BIS-10?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the iLINK-BIS-10 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the iLINK-BIS-10, and is it still sold?
The FDA's device database lists Oscor Inc. as the company responsible for it (brand iLINK-BIS-10, model iLINK-BIS-10). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Pacemaker Lead Adaptor devices
- Introducer Kit for Impella® 0052-3006Oscor Inc. · pacemaker lead Adaptor4 recalls223 deaths1,183 reports
- NA 5867-3MMedtronic, Inc. · pacemaker lead Adaptor25 reports
- Introducer Kit for Impella® 0052-3000Oscor Inc. · pacemaker lead Adaptor2 deaths19 reports
- Lead Adaptor BIS/BIS-40Oscor Inc. · pacemaker lead Adaptor14 reports
- NA 5866-38MMedtronic, Inc. · pacemaker lead Adaptor12 reports
- Lead Adapter 501206Greatbatch Ltd · Pacemaker Lead Adaptor10 reports
- NA 5867-3MMedtronic, Inc. · pacemaker lead Adaptor10 reports
- Lead Adapter 501214Greatbatch Ltd · Pacemaker Lead Adaptor9 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page