Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00840019900911), received between Dec 16, 2020 and Dec 16, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 16, 2020Break
IT WAS REPORTED THAT A PROCEDURE WAS PERFORMED ON (B)(6) 2020 IN THE UK, UTILIZING THE REFORM PEDICLE SCREW SYSTEM TO USE TWO SCREWS AND A ROD BENT TO A U-SHAPE TO BRIDGE ACROSS A PARS FRACTURE. A REDUCTION POLYAXIAL SCREW ASSEMBLY - Æ6.5MM X 35MM (39-RP-6535) WAS IMPLANTED ON THE LEFT SIDE OF L5 AND UPON ATTEMPTED INSERTION OF A REDUCTION POLYAXIAL SCREW ASSEMBLY - Æ6.5MM X 35MM (39-RP-6535) ON THE RIGHT SIDE THE PEDICLE BROKE. A HOOK WAS ATTEMPTED, BUT THE LAMINA FRACTURED. SUBSEQUENTLY, A REDUCTION POLYAXIAL SCREW ASSEMBLY - Æ5.5MM X 35MM WAS PLACED IN L4 ON THE RIGHT SIDE WITH THE ROD BENT TO TAKE THE LOAD OFF OF THE PARS FRACTURE. DURING FINAL TIGHTENING OF THE SET SCREW ON A RAMPED LAMINAR REDUCTION HOOK, MD, THE TIP OF THE LOCK-SCREW TORQUE DRIVER (39-RD-0060) BROKE. THE HOOK WAS REMOVED AND ANOTHER FROM THE SET USED. UPON FINAL TIGHTENING OF ONE OF THE LOCK-SCREWS THE TIP OF A SECOND LOCK-SCREW TORQUE DRIVER ALSO BROKE. THE BROKEN TIP WAS NOT ABLE TO BE RETRIEVED AND REMAINS IN THE HEAD OF THE POLYAXIAL SCREW, IMPLANTED IN THE PATIENT.
Patient problems: Foreign Body In Patient
MAUDE report 11015699 ↗
Other Orthosis, Spinal Pedicle Fixation devices
- NA 04.614.508Synthes GmbH · ORTHOSIS, SPINAL PEDICLE FIXATION277 reports
- CREO 1134.0010Globus Medical, Inc. · ORTHOSIS, SPINAL PEDICLE FIXATION112 reports
- CREO 1119.0010Globus Medical, Inc. · ORTHOSIS, SPINAL PEDICLE FIXATION80 reports
- VIPER 186731745Medos International Sàrl · ORTHOSIS, SPINAL PEDICLE FIXATION43 reports
- CD HORIZON® Spinal System 1553201090Medtronic Sofamor Danek, Inc. · ORTHOSIS, SPINAL PEDICLE FIXATION38 reports
- EXPEDIUM 179902000Medos International Sàrl · ORTHOSIS, SPINAL PEDICLE FIXATION37 reports
- CD HORIZON® Spinal System 7540220Medtronic Sofamor Danek, Inc. · ORTHOSIS, SPINAL PEDICLE FIXATION36 reports
- EXPEDIUM VERSE 199721640Medos International Sàrl · ORTHOSIS, SPINAL PEDICLE FIXATION35 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page