ShurFit Interbody Device TLIF30-08PRecalls & reported problems
Precision Spine, Inc. · TLIF Cage Peek 8mm x 30mm · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00840019909907), received between Jan 4, 2021 and Jan 12, 2021 — classified as 2 injuries.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Failure of Implant1
- Insufficient Information1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJan 12, 2021Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A 2 LEVEL REFORM TI AND SHURFIT TLIF CASE (L2 - L4) PERFORMED ON (B)(6) 2020. PER THE SURGEONS TECHNIQUE, HE PLACED THE REFORM TI SCREWS IN FIRST, DISTRACTED THE L2-3 DISC SPACE WITH A LAMINA SPREADER, CLEARED THE DISC WITH GENERAL SURGICAL INSTRUMENTS (KERRISONS, PITUITARIES, SHAVERS), AND THEN INSERTED THE 6MM SHURFIT TLIF TRIAL AND THEN THE 8MM SHURFIT TLIF TRIAL WITHOUT ANY ISSUES. BASED ON THE 8MM TRIAL SIZING, HE THEN INSERTED THE TLIF30-08P WITH THE SHURFIT INSERTER. UPON MALLETING THE BACK END OF THE INSERTER TO PLACE THE CAGE INTO THE DISC SPACE, THE TLIF CAGE BROKE IN-SITU. THE BROKEN PIECE WAS NOT IN THE DISC SPACE AND WAS ABLE TO BE REMOVED AND THE PROCEDURE COMPLETED UTILIZING A COMPETITOR'S INTERBODY IMPLANT WITHOUT ANY FURTHER ISSUES. THERE WAS A TEN (10) MINUTE DELAY TO THE PROCEDURE REPORTED.
Patient problems: Insufficient Information
MAUDE report 11155204 ↗InjuryJan 4, 2021Break
A 3-LEVEL MIS POSTERIOR FIXATION PLUS FUSION PROCEDURE WAS PERFORMED ON (B)(6) 2020 IN (B)(6), UTILIZING THE SURE-LOK MIS 3L SYSTEM. WHEN THE SURGEON WAS "PUNCHING" ON THE CAGE TO LOCATE IT IN ITS POSITION, THE TLIF CAGE PEEK 8MM X 30MM (TLIF30-08P) BROKE INSIDE THE PATIENT. THE SURGEON WAS ABLE TO REMOVE THE BROKEN CAGE AND ANOTHER WAS INSERTED SUCCESSFULLY. AFTER PLACING CAGES AND BEGINNING TO FIX THE SCREWS, WHILE PLACING THE SECOND ROD, THE SURGEON WAS INSERTING THE LOCK-SCREW, A STRANGE SOUND WAS HEARD, AND IT WAS FOUND THAT THE TIP OF THE CL ROD INSERTER (63-CL-9005) WAS BROKEN OFF. THE BROKEN PIECE WAS REMOVED AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY AS THE ROD WAS ALREADY IN PLACE. THERE WAS NO PATIENT HARM REPORTED, BUT THERE WAS A ONE (1) HOUR DELAY TO THE PROCEDURE AS A RESULT OF THESE MALFUNCTIONS.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Failure of Implant
MAUDE report 11108462 ↗
Other Intervertebral Fusion Device With Bone Graft, Lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page