Resp-O2 Pressure Line Adaptor, 22 mm OD x 22 mm ID Connections 34513Recalls & reported problems
Dynarex Corporation · Barbed Elbow Accepts 5 mm to 7 mm ID Tubing, Elbow Swivels 360 · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00840117340305), received between Jun 2, 2026 and Jun 2, 2026 — classified as 1 injury.
The most frequently reported specific device problem is “Manufacturing, Packaging or Shipping Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Manufacturing, Packaging or Shipping Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 2, 2026Manufacturing, Packaging or Shipping Problem
FIRST EVENT 19-DEC-2025 IN THE INITIAL INCIDENT, THE PATIENT WAS ON A TRACHEOSTOMY COLLAR AND HAD BEEN PLACED ON A NEW AIRWAY CARE SETUP, WHICH INCLUDED THE PRESSURE LINE ADAPTER. AFTER BEING PLACED ON THIS SETUP, HE PATIENTS'S OXYGEN SATURATION LEVELS DECLINED. ALTHOUGH THE PATIENT IS NORMALLY OFF THE VENTILATOR, THE DESATURATION REQUIRED PLACEMENT ON A VENTILATOR FOR APPROXIMATELY TWELVE HOURS. SECOND EVENT 17-FEB-2026 A SECOND OCCURENCE WAS IDENTIFIED THIS WEEK, THE SAME PATIENT WAS INVOLVED. A RESPIRATORY THERAPIST NOTED BACK PRESSURE ON THE HUMIDIFIER, AND THE WATER BOTTLE WAS EXPANDING. THIS PROMPTED FURTHER INVESTIGATION, WHICH REVEALED AN OCCLUDED ADAPTOR. THE REPORT ISSUE INVOLVES THE ELBOW OF THE ADAPTOR. AT THIS LOCATION, PLASTIC MATERIAL WAS FOUND FULLY OCCLUDING THE TURN WITHIN THE ADAPTOR. NOTE: DYNAREX WAS NOT CONTACTED ABOUT THE FIRST EVENT AND WAS NOT AWARE OF IT UNTIL THE SECOND EVENT WAS REPORTED TO OUR ATTENTION. INCIDENT LOCATION: (B)(6). CONTACT: (B)(6).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25360209 ↗
Other Tubing, Pressure And Accessories devices
- O2 Cannula 001350Salter Labs · Tubing, Pressure And Accessories93 reports
- AirLife 2002-7Salter Labs · TUBING, PRESSURE AND ACCESSORIES6 reports
- AirLife SO-1968-0Salter Labs · TUBING, PRESSURE AND ACCESSORIES3 reports
- O2 Tubing 001304USalter Labs · Tubing, Pressure And Accessories3 reports
- AirLife SO-1188-0Salter Labs · TUBING, PRESSURE AND ACCESSORIES3 reports
- Flow sensor 155500Hamilton Medical AG · Tubing, Pressure And Accessories2 reports
- AirLife 2025G-25Salter Labs · TUBING, PRESSURE AND ACCESSORIES2 reports
- HUDSON RCI HUD1115Medline Industries, Inc. · TUBING, PRESSURE AND ACCESSORIES2 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page