SWANSON 4700002Recalls & reported problems
Wright Medical Technology, Inc. · Class 2 · Implant
All models of SWANSON (11)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00840420121684), received between Jan 9, 2023 and Sep 14, 2026 — classified as 3 injuries, 1 malfunction.
The most frequently reported specific device problem is “Fracture” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Fracture2
Patient problems
- Loss of Range of Motion2
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjurySep 14, 2026Fracture
As reported: \"Material fatigue fracture; as a result, this patient had to undergo revision surgery. The implant was originally fitted at the (b)(6). Surgery on (b)(6) 2023 ¿ implantation of a Swanson prosthesis in the left thumb. The customer originally assumed that the device was a Keriflex prosthesis. However, Keriflex informed the customer that it is in fact a Swanson product. The customer has submitted the updated user report to the Swissmedic regulatory authority.\"
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50765168 ↗MalfunctionJan 16, 2026Fracture
IT WAS REPORTED THAT THE PHYSICIAN HAD IMPLANTED A SIZE 2 SWANSON FLEXIBLE FINGER IMPLANT. THE IMPLANT BROKE A DAY AFTER THE PROCEDURE. NO ADDITIONAL INFORMATION WAS AVAILABLE.
Patient problems: Insufficient Information
MAUDE report 24094986 ↗InjuryOct 27, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A SURGICAL PROCEDURE TO REPLACE THE JOINTS FROM II THROUGH V WITH SWANSON IMPLANTS. 9 WEEKS AFTER HAND SURGERY, FIST CLOSURE IS IMPOSSIBLE. THE FINGER BASE JOINTS ARE HARDLY MOVABLE.
Patient problems: Loss of Range of Motion
MAUDE report 18022547 ↗InjuryJan 9, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY THE CUSTOMER THAT 'ARHTROPLASTY OF THE SWANSON OF THE PPI IN 2013 AND FUNCTIONAL IMPOTENCE FOR 6 MONTHS: IMPLANT CHANGE + BIOPSY'.
Patient problems: Loss of Range of Motion
MAUDE report 16125620 ↗
FDA clearance and classification
The FDA regulates product code KWF (prosthesis, finger, polymer) under 21 CFR 888.3230 as a Class II device. 21 CFR 888.3230 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the SWANSON 4700002
Has the SWANSON 4700002 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00840420121684), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the SWANSON 4700002?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Jan 9, 2023 and Sep 14, 2026. In those reports, the most common specific device problem is “Fracture” (2); the most common patient problem is “Loss of Range of Motion” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the SWANSON 4700002?
None of the reports are classified as deaths, 3 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the SWANSON 4700002 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the SWANSON 4700002, and is it still sold?
The FDA's device database lists Wright Medical Technology, Inc. as the company responsible for it (brand SWANSON, model 4700002). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other PROSTHESIS, FINGER, POLYMER devices
- SWANSON 4700020Wright Medical Technology, Inc. · PROSTHESIS, FINGER, POLYMER1 recall0 reports
- SWANSON G4700003Wright Medical Technology, Inc. · PROSTHESIS, FINGER, POLYMER2 reports
- SWANSON G4700004Wright Medical Technology, Inc. · PROSTHESIS, FINGER, POLYMER2 reports
- SWANSON 4700001Wright Medical Technology, Inc. · PROSTHESIS, FINGER, POLYMER1 report
- SWANSON 4700010Wright Medical Technology, Inc. · PROSTHESIS, FINGER, POLYMER1 report
- SWANSON G4700006Wright Medical Technology, Inc. · PROSTHESIS, FINGER, POLYMER1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page