Transitionless Micro-Introducer Kit KIT-038-03Recalls & reported problems
Galt Medical Corp. · Transitionless Micro-Introducer Kit · Class 2
All models of Transitionless Micro-Introducer Kit (3)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00841268104549), received between Nov 30, 2018 and Nov 9, 2023 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Physical Resistance/Sticking1
Patient problems
- No Known Impact Or Consequence To Patient2
- Foreign Body In Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryNov 9, 2023
DURING AN ATTEMPT TO PLACE A MIDLINE CATHETER, THE GUIDEWIRE BECAME STUCK IN THE PATIENT'S ARM (NOTED TO BE LOCATED IN SUBCUTANEOUS TISSUE). THERE WAS DIFFICULTY IN BACKING THE WIRE OUT, THEREFORE, VASCULAR SURGERY WAS CONSULTED. AS ATTEMPTS WERE BEING MADE AT WIRE REMOVAL BY VASCULAR SURGERY, THE WIRE BROKE. A MEDICAL DECISION WAS MADE TO LEAVE THE BROKEN PIECE OF THE WIRE INSIDE THE PATIENT. THIS WAS REPORTED AS THE 3RD TIME IN WHICH THIS PROCEDURALIST HAS SEEN THE WIRE TIP ENCIRCLE ITSELF INTO FORMING A SMALL KNOT. IN THE PREVIOUS 2 CASES, THE WIRE WAS SIMPLY REMOVED. IN THIS CASE, THE WIRE BECAME STUCK AND REQUIRED CONSULTATION BY VASCULAR SURGERY AND A TRIP TO THE OPERATING ROOM FOR ATTEMPTED REMOVAL OF THE WIRE. NOTE: THIS GUIDEWIRE WAS USED WHILE ATTEMPTING TO PLACE A BARD POWERMIDLINE CATHETER.
Patient problems: Foreign Body In Patient
MAUDE report 18122243 ↗MalfunctionDec 17, 2018Break
AS RECEIVED FROM HEALTH PROFESSIONAL: PATIENT WAS PREPPED/ DRAPED IN STERILE FASHION. PER CARDIOLOGIST'S NOTES: A PERCUTANEOUS NEEDLE STICK WAS ACHIEVED THROUGH THE LEFT SUBCLAVIAN VEIN. A GUIDEWIRE WAS THEN INSERTED INTO THE LEFT SUBCLAVIAN VEIN. RESISTANCE WAS MET AND WHILE RETRACTING THE WIRE, THE TIP BROKE OFF. CONTRAST ANGIOGRAPHY WAS PERFORMED DEMONSTRATING THAT THE WIRE WAS NOT INTRAVASCULAR. ACCESS WAS THEN AGAIN ACHIEVED VIA MICROPUNCTURE UNDER ANGIOGRAPHY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8171754 ↗MalfunctionNov 30, 2018Break; Physical Resistance/Sticking
PATIENT WAS PREPPED/ DRAPED IN STERILE FASHION. PER CARDIOLOGIST'S NOTES: A PERCUTANEOUS NEEDLE STICK WAS ACHIEVED THROUGH THE LEFT SUBCLAVIAN VEIN. A GUIDEWIRE WAS THEN INSERTED INTO THE LEFT SUBCLAVIAN VEIN. RESISTANCE WAS MET AND WHILE RETRACTING THE WIRE, THE TIP BROKE OFF. CONTRAST ANGIOGRAPHY WAS PERFORMED DEMONSTRATING THAT THE WIRE WAS NOT INTRAVASCULAR. ACCESS WAS THEN AGAIN ACHIEVED VIA MICROPUNCTURE UNDER ANGIOGRAPHY. MANUFACTURER RESPONSE FOR PERCUTANEOUS SHEATH INTRODUCER KIT, TRANSITIONLESS MICRO-INTRODUCER KIT (PER SITE REPORTER). REPORTED BY THE CARDIAC CATH LAB MANAGER TO MANUFACTURER.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8119529 ↗
Other Percutaneous Sheath Introducer Kit devices
- Transcarotid/Peripheral Access Kit KIT-075-03Galt Medical Corp. · Percutaneous Sheath Introducer Kit1 recall12 reports
- Micro-Introducer Kit KIT-002-28Galt Medical Corp. · Percutaneous Sheath Introducer Kit1 recall2 reports
- Transitionless Stiffen Micro-Introducer Kit KIT-039-03Galt Medical Corp. · Percutaneous Sheath Introducer Kit1 recall2 reports
- Transitionless Micro-Introducer Kit KIT-038-04Galt Medical Corp. · Percutaneous Sheath Introducer Kit1 recall1 report
- Stiffen Micro-Introducer Kit KIT-011-62Galt Medical Corp. · Percutaneous Sheath Introducer Kit1 recall1 report
- Posi-Stick® Introducer Kit KIT-081-02Galt Medical Corp. · Percutaneous Sheath Introducer Kit1 recall0 reports
- Stiffen Micro-Introducer Kit KIT-011-40Galt Medical Corp. · Percutaneous Sheath Introducer Kit1 recall0 reports
- Micro-Introducer Kit KIT-002-35Galt Medical Corp. · Percutaneous Sheath Introducer Kit1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page