Cabo™ 81-1216Recalls & reported problems
Neurostructures, Inc · Variable - 4.0mm Self Tapping 16mm · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00841508101673), received between Oct 24, 2017 and Jan 26, 2018 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Fracture” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Fracture5
- Mechanical Problem2
Patient problems
- Failure of Implant5
- Device Embedded In Tissue or Plaque1
- No Code Available1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 26, 2018Fracture; Mechanical Problem; Fracture; Mechanical Problem
SURGEON HAD TO REVISE AN ACDF PATIENT THAT WAS JUST OVER 3 MONTHS OUT. PHYSICIAN NOTED AT 3 WEEKS THAT ONE OF THE SCREWS ON THE BOTTOM OF THE PLATE HAD BACKED OUT "ONE TURN". HE DID NOT SURGICALLY INTERVENE AT THAT TIME. THE PATIENT LATER REPORTED HEARING A POP (APPROXIMATELY 13 WEEKS POST-OP). THE PATIENT WAS SEEN BY THE SURGEON AFTER THIS EVENT. THE X-RAY REVEALED THE BOTTOM SCREW HAD BACKED OUT FURTHER, AND BOTH OF THE TOP SCREWS WERE BROKEN CLOSE TO MID-SHAFT. THE SURGEON TOOK THE PATIENT BACK TO SURGERY AND REMOVED THE PLATE AND SCREWS, EXCEPT FOR THE 2 BROKEN TIPS WHICH HE LEFT IN THE BONE. THE SURGEON CHOSE NOT TO RE-PLATE. THE PATIENT WAS PUT IN A HARD COLLAR AND WILL BE MONITORED TO SEE IF FURTHER INTERVENTION IS NEEDED.
Patient problems: Failure of Implant
MAUDE report 7223037 ↗MalfunctionJan 26, 2018Fracture; Mechanical Problem; Fracture; Mechanical Problem
SURGEON HAD TO REVISE AN ACDF PATIENT THAT WAS JUST OVER 3 MONTHS OUT. PHYSICIAN NOTED AT 3 WEEKS THAT ONE OF THE SCREWS ON THE BOTTOM OF THE PLATE HAD BACKED OUT "ONE TURN". HE DID NOT SURGICALLY INTERVENE AT THAT TIME. THE PATIENT LATER REPORTED HEARING A POP (APPROXIMATELY 13 WEEKS POST-OP). THE PATIENT WAS SEEN BY THE SURGEON AFTER THIS EVENT. THE X-RAY REVEALED THE BOTTOM SCREW HAD BACKED OUT FURTHER, AND BOTH OF THE TOP SCREWS WERE BROKEN CLOSE TO MID-SHAFT. THE SURGEON TOOK THE PATIENT BACK TO SURGERY AND REMOVED THE PLATE AND SCREWS, EXCEPT FOR THE 2 BROKEN TIPS WHICH HE LEFT IN THE BONE. THE SURGEON CHOSE NOT TO RE-PLATE. THE PATIENT WAS PUT IN A HARD COLLAR AND WILL BE MONITORED TO SEE IF FURTHER INTERVENTION IS NEEDED.
Patient problems: Failure of Implant
MAUDE report 7222557 ↗MalfunctionNov 2, 2017Fracture; Fracture
POST-OP LEFT SIDE CAUDAL SCREW FRACTURE. POST-OP RIGHT SIDE SCREW BACK OUT. SURGERY ON (B)(6) 2017. FOUND ON ROUTINE FOLLOW UP BY CLINICIAN. THE SAME CLINICIAN AS PER (B)(4) AND (B)(4). PATIENT ASYMPTOMATIC, PLAN WILL BE TO MONITOR PATIENT.
Patient problems: Failure of Implant
MAUDE report 6998232 ↗MalfunctionOct 24, 2017Fracture; Fracture
POST-OP SCREW BREAKAGE IN PATIENT. C4-6 ACDF. SURGERY (B)(6) 2017. FOUND ON ROUTINE FOLLOW UP BY CLINICIAN. THE SAME CLINICIAN AS PER (B)(4). PATIENT ASYMPTOMATIC, PLAN WILL BE TO MONITOR PATIENT.
Patient problems: Failure of Implant; No Code Available
MAUDE report 6973506 ↗MalfunctionOct 24, 2017Fracture; Fracture
POST-OP SCREW BREAKAGE IN PATIENT. C5-7 ACDF. SURGERY (B)(6) 2017. FOUND ON ROUTINE FOLLOW UP. PATIENT ASYMPTOMATIC, PLAN WILL BE TO MONITOR PATIENT.
Patient problems: Device Embedded In Tissue or Plaque; Failure of Implant
MAUDE report 6973117 ↗
Other Appliance, Fixation, Spinal Intervertebral Body devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- Mariner RDX MX1-000040Seaspine Orthopedics Corporation · Appliance, fixation, spinal intervertebral body1 recall0 reports
- Mariner RDX MX1-000030Seaspine Orthopedics Corporation · Appliance, fixation, spinal intervertebral body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430112Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430224Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- XLP 7565050Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page